NOTES:
Honeywell requires the use of a GFI circuit on this device to protect the homeowner from electrical shock.
When installed correctly, the green wire should be removed from the drain valve. The green wire comes pre-installed
from the factory to protect the homeowner in case of an improper installation or when it is not possible to retrofit a GFI
circuit. See Fig. 24 for the location of green wire on the drain valve.
Ensure that adequate power is available to carry full humidifier amp draw as indicated on the specification label.
Do not use neutral wire as a ground; connect a dedicated ground to ground termination.
All wiring to be in accordance with national and local electrical codes.
240 VAC (1 PHASE)
GROUND
HOT
HOT
(OPTIONAL)
120 VAC (1 PHASE)
GROUND
NEUTRAL
HOT
NOTE: CONNECT 120 VAC,
"HOT", TO L1
(OPTIONAL)
Fig. 16. Primary power connection.
11
NOTE: POWER WIRES
CAN ALSO BE ROUTED
THROUGH OPENING IN
BACK OF CABINET
GROUND
P
240
120
L1
GROUND
P
240
120
L1
E
I
X
N
T
T
M35806
HM700A1000
33-00118EFS—03