BTL7-S5 _ _ ( _ )-M _ _ _ _ -A/B(8)-SA211/SA311-S147
Transducer — Rod Style
Electrical connection
BTL7 standard
Pin
BTL7-S5_ _...-S147
1
–Data
2
+Data
3
+Clk
4
–Clk
5
10...30 V
6
GND
7
Not used 1)
Shielding and cable routing
Defined ground!
The transducer and the control cabinet must be
at the same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
–
Connect transducer and controller using a shielded
cable. Shielding: Braided copper shield with
minimum 85%.
–
Connector version: Shield is internally connected to
connector housing.
Magnetic fields
The position measuring system is a magnetostrictive
system. It is important to maintain adequate distance
between the transducer/holding cylinder and strong,
external magnetic fields.
Cable routing
Do not route the cable between the transducer, controller,
and power supply near high voltage cables (inductive stray
noise is possible). The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Installation
NOTICE!
Interference in function
Improper installation can compromise the function of the
transducer and result in increased wear.
► The mounting surface of the transducer must make
full contact with the supporting surface.
► The bore must be perfectly sealed (O-ring/flat seal).
Screw the BTL thread into the mounting hole (max. torque
100 Nm).
www.balluff.com
Pin assignment of S147 (view from above on transducer), 7-pin
M16 circular plug
1) Unassigned leads can be connected to GND on the controller side but
not to the shield.
For horizontal assembly with nominal lengths > 500 mm,
support the rod and tighten it at the end if necessary (only
possible with a diameter of 10.2 mm).
If installed in a hydraulic cylinder, the magnet should not
make contact with the rod. Minimum bore diameter in the
support piston:
Rod diameter
10.2 mm
8 mm
Startup
DANGER
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
(especially after replacing the transducer or after repair
by the manufacturer). Recalibrate the transducer, if
necessary.
Operating notes
–
Check the function of the transducer and all associated
components on a regular basis.
–
Take the position measuring system out of operation
whenever there is a malfunction.
–
Secure the system against unauthorized use.
Bore diameter
At least 13 mm
At least 11 mm
english
2