BTL5-H1A/C/E _ -M _ _ _ _ -A/B/Y/Z(8)-C001
Micropulse Transducer - Rod Style
EU Directive 2004/108/EG (EMC Directive) and EMC law
Generic standards: EN 61000-6-4 (emission), EN 61000-6-2 (noise immunity)
Emission tests: RF emission EN 55016-2-3 Group 1, Class A and B
Intended use
The BTL5 Micropulse Transducer, together with a machine
controller (e.g. PLC), comprises a position measuring
system. It is intended to be installed into a machine or
system. Flawless function in accordance with the
specifications in the technical data is ensured only when
using original BALLUFF accessories, use of any other
components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer,
it should be taken out of service and secured against
unauthorized use.

Downloading further instructions

A complete user's and configuration guide can be
downloaded from the Internet at
www.balluff.com/downloads-btl5 or requested via
e-mail from CANopen@balluff.de.
Dimensions and function
The BTL5 transducer contains the waveguide which is
protected by an outer stainless steel tube (rod). A magnet
is moved along the waveguide. This magnet is connected
to the system part whose position is to be determined.
Mounting surface

Electrical connection

BTL5...B/Z-C001
Not usable range
1)
Not included
2)
1
english
B: 30-1 mm
Z: 2"-0.04"
Nominal length =
Measuring range
1)
Magnet
2)
Thread size:
B: M18x1.5
Z: 3/4"-16UNF
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A/B/Y/Z(8)-...
8 mm
Electrical connection
The connection assignments can be found in the following
tables and figures:
Pin
Control and data signals
1
CAN_GND
4
CAN_H
5
CAN_L
Pin
Supply voltage (external)
3
0 V (GND)
2
+24 V
1)
1)
Please note that 24 V must be applied here and not 5 V as used for CAN
drivers.
BTL5-H1...C001 (BUS IN/OUT) connection assignments
1
1
4
2
2
4
5
3
5
3
BUS OUT
BUS IN
CAN (BUS IN/OUT)
pin assignments
Pin
Connection for analog sensors
1
+24 V (sensor supply)
2
0 V (GND for sensors)
3
Sensor input 1
4
Sensor input 2
BTL5-H1...C001 connection assignments for the analog inputs
Damping zone
1)
Mounting surface
BTL5...A/Y-C001
G
Thread
M4x4/6 deep
w/o thread
File No.
E227256
1
3
2
4
Pin assignment, M8 plug,
4-pin (view from above on
socket)
A: 30-1 mm
Y: 2"-0.04"
1)
Thread size:
A: M18x1.5
Y: 3/4"-16UNF