2.2 - INSTALL THE SENSOR PAD ON THE MATTRESS SUPPORT
IMPORTANT
If your crib does not have a solid, stable surface for the Sensor Pad, you will need to place a
support under it, to ensure correct operation of the system.
This hardboard support should be at least 1/4'' (6 mm) thick and should have minimum dimensions
of 13'' x 13'' (33 x 33 cm). This support board must be larger than the Sensor Pad surface area.
The Sensor Pad functions with any size and type of mattress except memory-foam mattresses,
hollow frame mattresses and water beds. The hardboard maintains a constant pressure on the
Sensor Pad, enabling it to detect the baby's movements even when the baby is at the edges of the
crib.
Sensor Pad
WARNING -
• The Sensor Pad is not designed for use with adults, children or infants older than 24 months.
• Discontinue used of the Sensor Pad when child is older than 24 months. Remove Sensor Pad from crib
and store for future use.
• BEFORE FIRST TIME USE: To test that the unit is ready for use, refer to instruction manual on how to test
that the installation has been done correctly.
STEP 3 - TURNING ON YOUR MONITOR
Press and hold the Nursery Unit
ON/OFF button for
2 seconds until the Nursery Unit
Indicator flashes slowly in green.
1) Remove the battery cover using a coin. Turn in
the direction of the arrow.
2) Place the included battery (CR3032) in the
compartment. Note: The + symbol should be
facing up.
3) Replace the battery cover (the two dots will line
up). The Sensor Pad is now ON.
2
1) Remove the mattress from the crib.
2) Place the Sensor Pad - Angelcare
up - in the center of the mattress. It should be
centered on the hardboard if your crib requires
a hardboard support.
3) Replace the mattress.
The Nursery Unit will emit a sound and flash blue to
confirm pairing with the Sensor Pad
NOTE:
If the green light does not appear but the red
light is flashing; or if there are false alarms,
adjust the sensitivity level (Step 4.3).
E
N
Hardboard
logo side
®
5