ABB MT Serie Manual De Instalación, Funcionamiento, Mantenimiento Y Seguridad página 16

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
Lubrication intervals according to L
Amount
Frame
of grease
size
g/bearing
112
10
132
15
160
25
160
25
180
30
180
30
200
40
200
40
225
50
225
50
250
60
250
60
280
60
1)
280
60
1)
280
35
280
40
315
35
315
55
355
35
355
70
400
40
400
85
450
40
450
95
160
25
160
25
180
30
180
30
200
40
200
40
225
50
225
50
250
60
250
60
280
60
1)
280
70
1)
280
35
280
40
315
35
315
55
355
35
355
70
400
40
400
85
450
40
450
95
1) M3AA
For motors M4BP 160 to 250 the interval may be increased by 30 %, up to a maximum of three calendar years.
The values in table above are valid also for sizes M4BP 280 to 355.
EN-16
principle
1
3600
3000
kW
r/min
r/min
Lubrication intervals in duty hours
all
10000
13000
all
9000
11000
≤ 18,5
9000
12000
> 18,5
7500
10000
≤ 22
7000
9000
> 22
6000
8500
≤ 37
5500
8000
> 37
3000
5500
≤ 45
4000
6500
> 45
1500
2500
≤ 55
2500
4000
> 55
1000
1500
all
2000
3500
-
-
-
all
1900
3200
-
-
all
1900
3200
-
-
all
1900
3200
-
-
all
1500
2700
-
-
all
1500
2700
-
-
Lubrication intervals in duty hours
≤ 18,5
4500
6000
> 18,5
3500
5000
≤ 22
3500
4500
> 22
3000
4000
≤ 37
2750
4000
> 37
1500
2500
≤ 45
2000
3000
> 45
750
1250
≤ 55
1000
2000
> 55
500
750
all
1000
1750
-
-
-
all
900
1600
-
-
all
900
1600
-
-
all
900
1600
-
-
all
-
1300
-
-
all
-
1300
-
-
1800
1500
kW
r/min
r/min
Ball bearings
all
18000
21000
all
17000
19000
≤ 15
18000
21500
> 15
15000
18000
≤ 22
15500
18500
> 22
14000
17000
≤ 30
14500
17500
> 30
10000
12000
≤ 45
13000
16500
> 45
5000
6000
≤ 55
9000
11500
> 55
3500
4500
-
-
-
all
8000
10500
-
-
all
7800
9600
-
-
all
5900
7600
-
-
all
4000
5600
-
-
all
3200
4700
-
-
all
2500
3900
Roller bearings
≤ 15
9000
10500
> 15
7500
9000
≤ 22
7500
9000
> 22
7000
8500
≤ 30
7000
8500
> 30
5000
6000
≤ 45
6500
8000
> 45
2500
3000
≤ 55
4500
5500
> 55
1500
2000
-
-
-
all
4000
5250
-
-
all
4000
5300
-
-
all
2900
3800
-
-
all
2000
2800
-
-
all
1600
2400
-
-
all
1300
2000
ABB/Manual for Low Voltage Motors 01-2009
1000
kW
kW
r/min
all
25000
all
all
23000
all
≤ 11
24000
all
> 11
22500
all
≤ 15
24000
all
> 15
21000
all
≤ 22
23000
all
> 22
16000
all
≤ 30
22000
all
> 30
8000
all
≤ 37
15000
all
> 37
6000
all
-
-
-
all
14000
all
-
all
13900
all
-
all
11800
all
-
all
9600
all
-
all
8600
all
-
all
7700
all
≤ 11
12000
all
> 11
11000
all
≤ 15
12000
all
> 15
10500
all
≤ 22
11500
all
> 22
8000
all
≤ 30
11000
all
> 30
4000
all
≤ 37
7500
all
> 37
3000
all
-
-
-
all
7000
all
-
all
7000
all
-
all
5900
all
-
all
4800
all
-
all
4300
all
-
all
3800
all
500-900
r/min
28000
26500
24000
24000
24000
24000
24000
20000
24000
10000
18000
7000
-
17000
-
15000
-
12900
-
10700
-
9700
-
8700
12000
12000
12000
12000
12000
10000
12000
5000
9000
3500
-
8500
-
8500
-
6500
-
5400
-
4800
-
4400

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido