It is the responsibility of the installer/owner to ascertain
compliance with specific local regulations prior to installa-
tion.
Jacuzzi Europe S.p.A. gives no guarantee in this respect
and refuses all responsibility regarding compliance of the
installation carried out.
Technical Features
i
Alimia Experience (
1) includes:
- a control unit, called "Spa-Pak"
it is possible to additionally add a spa-pak "booster kit"
NOTE:
i
(optional,
2-2a, n°33
supplied as standard; refer to the relative documenta-
tion.
i
- the balance tank (
1, V/V1
to hold water that overflows when users get into the tub. Its nomi-
nal capacity is 1,000 litres (operating with about 800-850 litres).
i
- the Hot tub (
1, C), is to be connected, with hoses, to the "Spa-
Pak", the balance tank and the drain.
MAXIMUM ABSORPTION FOR THE SYSTEM
SINGLE-PHASE TOP
• version with heater
Power supply (x)
Volt
Hertz
Ampere
220-240 ~
50/60
25,5 (k)
• version with exchanger
Power supply (x)
Volt
Hertz
220-240 ~
50/60
19,5 (k)
(k): at 230 V - (j): power absorption
(x): see the "electrical preparations" chapter
THREE-PHASE
Alimentazione
Consumo tot. riscaldatore
(trifase)
elettrico+pompe+fari
Volt
Hertz
Ampere
(*)
50/60
220 - 240 3~
45
50/60
26
380 - 415 3N~
(*): special standard (non valido per l'Europa)
WEIGHTS
HOT TUB
Net weight
average fill
kg
litres
~ 1350
~180
concentrated load on
resting surface
resting surface
m
2
kg/m
2
~1,12
~1643
i
.
(
1, A)
) to be connected to the one
) which, once connected, is required
Total consumption
hydro + filtering + heater
(3 kW)
kW
5,75 (j)
Total consumption
hydro + filtering
Ampere
kW
4,25 (j)
(12 kW)
Consumo tot. solo pompe e fari
(vers. scambiatore)
kW
Ampere
(j)
17
13
(j)
17
8
(j): potenza assorbita max.
maximum
max. weight
water volume
litres
~ 1660
~1840
LOWERED
BALANCE TANK (V1)
BALANCE TANK (V)
SPA-PAK
Heat exchanger (optional)
- MAX primary circuit temperature .............................................................50 °C
- Connections.....................................................................................................................3/4"
- Primary circuit flow rate ..............................................................................38 l/min
- Primary pressure drop .....................................................................0,271 m H 2 O
Components
Components and the necessary connections for setting up the system
are described below (see
Hot tub and plumbing
1
overflow channel with grid
2
buttons
2a
box for connection of buttons
3
low-point drain with gate valve
to the balance tank (overflow lines)
4A1+4B1
4A2+4B2
to the balance tank (overflow lines)
4C1/4C2
from the overflow channel (overflow lines)
5
hydromassage pump suction lines
6
hydromassage pump delivery lines
7
filtering suction line
8
suction line from the balance tank
9
filtering return line
10
blower line (optional)
11
connections to the water system
12
perimeter metal supports
Spa-pak
13, 13a Electric wiring box
14
optional - 14b: heater or 14a: heat exchanger
15
hydromassage pumps
16
filtering pump
17
blower
18
quartz sand filter
kW
19
safety switch
(j)
5
20
temperature sensor
(j)
5
21
flow switch (models with heater)
balance tank
22
water loading/filling solenoid valve (3/4")
23
level switches
24
check valve
Total
25
gate valve (for emptying)
kg
26
pre-filters
27
overflow
28, 29
ground drainage points
30
gate valves (for system maintenance)
31
gate valves (for suction balancing)
16
max weight
ground resting surface
at full load
kg
m
2
~ 900
~ 1,8
~ 925
~ 1,2
~ 285
~ 1,1
i
2-2a).
ground load
kg/m
2
~ 500
~ 770
~ 260