4
STEP
Opening
sensitivity
5
STEP
Closing
sensitivity
6
STEP
Type of
radio (Fixed
or Roller
code)
7
STEP
Semi-auto
or auto and
closing and
standby
time
8
STEP
Slowdown
distance in
closing
9
STEP
Mode in
opening
10
STEP
Operation
counter
CL: door closed
Display
CL (flashing):
indications
F1: failure due to current
during use
E1: failure due to encoder
12
In steps 4 to 10, programming can be finished early by keeping SET pressed down.
Press SET to confirm
Press SET to confirm
Press SET to confirm
Press SET to confirm
Press SET to confirm
Press SET to confirm
door closing
Number of operations in hundreds:
02: 200 operations, 30: 3000 operations,
1.4: 14000 operations,
max. 5.9 (59,000 operations)
OP: door open
OP (flashing):
door opening
30, 29, 28 ... : countdown in
automatic closing
Select the value by pressing |+ / |- :
1: maximum sensitivity;
...;
6: minimum
Select the value by pressing |+ / |- :
1: maximum sensitivity;
...;
6: minimum
Press |+ / |- to select fixed code (F)
or Roller Code (r). The code can be
personalised by enabling the
transmitter seed (bridge or button)
of the personalised transmitter
whilst r is flashing. The display will
show r. The memory must be
empty in order to change from r to
F or from r to r..
Select mode and standby time by
pressing |+ / |- :
00: semi-auto;
01: auto, 1s; ...;
30: auto, 30s;
1.0: auto, 1 min;
1.1: auto, 1 min 10s;
4.0: auto, 4 min
Select the slowdown distance by
pressing |+ / |- :
1: 50 mm (in the track);
2: 100 mm;
3: 250 mm; 4: 500 mm
Select the value by pressing |+ / |- :
0: alternative shutdown + optional
automatic closing;
1: opening without alternative
shutdown + restart standby time
END OF PROGRAMMING
St: stop
rS
(static): waiting for reset
rS
(flashing): reset
C5: shutdown by closing photocell
PA: pause
...;
M260B1