GB
5. Installation precautions
CAuTIon: Make sure there is a distance of at least 2 meters between each product, except between two detectors.
The motion detector must be placed:
• with an installation height from 0.8 to 1.2 m
high,
H
• perpendicular to the ground, so that the
zone of higher detection is parallel to the
ground. If the detector is tilted compared to
the ground, the reliability of operation can
be reduced,
• so that the detection beams are parallel to
the wall.
The motion detector must not be placed:
• in an area likely to receive direct sunlight or
a very powerful light source,
72
• facing moving objects (branches, bushes,
flags, etc),
• away from the wall (must not be used for
infrared barrier type perimeter protection),
• directly on to a metal wall or close to
sources of interference (electricity meters,
etc.) or ventilation such as air-conditioning
grilles.