Rocal G Serie Manual De Caracteristicas, Instalacion Y Funcionamiento página 18

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

3. DETECTION OF MALFUNCTION
The table below shows the possible malfunctions, what brought them about and the solutions to
follow:
MALFUNCTION
1. Smoke mislead or
insufficient air intake.
2. Glass (too dirty)
3. Whitening of the glass or
damage the color of the plate
4. Little heating
5. Smoke going out through
front door.
6. The opening mechanism of
the door does not work
7. The door slides up and
down without any help
8. Cracks in some parts of
vermiculite inside
CAUSE
Inadequate pipe.
Insufficient air for combustion
Inadequate pipe.
Inadequate fuel.
Upper deflected panel misadjusted
Excess temperature caused by an
excessive fire in the combustion
chamber
Inadequate fuel.
Inadequate air inlet to smokestack
First lit.
Flammable or combustible elements
inside the fireplace or around.
Crack in the flue.
Upper deflected panel misadjusted
Block of the change mechanism
Incorrectly adjusted counterweights
Beat in one of the pieces performed,
especially at the time of recharge
SOLUTION
Check pipe:
-connection
-diameter
-leaks
-insufficient length
-outlet
-blockage
Check the flue draught entry
Other ventilation or heating device work
simultaneously
Check pipe
Use authorized fuel
Adjust according directions
Check the fuel load
Set the registers according to paragraph 2.2.
Authorized fuel
Check chamber and seal to the flue
Wait for the polymerisation process (more than
one lit)
Check insulation material (glass fibre, igneous
wood or other elements), possibly replace them
Check for cracks and call dealer
Adjust according directions.
Release the door from the closing pressure
raising it a few centimetres.
Adjust the counterweights adding or removing
plates.
(Sect. 1.4.)
Try not to pull the logs but put
Perform charging where the temperature of the
combustion chamber has decreased
NOTE: If the part is only cracked but does
not move from your site, you can continue
using the device with absolute normality
section 2.6. Loading and refueling)
(see
Pag. 18

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

G 300G 350G 400G 450G 500

Tabla de contenido