Configuration Settings - Baxtran SNU Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SNU
Please open up to outer case of indicator before calibrate, plug the circuit breaker JP1 into 'on'.
STEP 1: ENTER SETUP
Press and hold
will display. Press
STEP 2: DIVISION
Either 'd1 X.XXX' or 'd2 X.XXX' will display.
'd1' is the division for single range display (from 0.0001-50)
'd2' is the smaller division for the dual range display (from 0.0001-50)
Example
For a 60 kg scale, if 'd1' is set to 0.02 kg, the scale will show a division of 0.02 kg among 0 kg - 60 kg.
If 'd2' is set to 0.005 kg, the scale will show a division of 0.005 kg from 0-30 kg and show a division of 0.01
kg among 30-60 kg.
Press
to switch between 'd1' and 'd2'.
Press
to change division.
Press
to confirm and enter into the next step.
Note: if 'd1' is set, the scale will only be in single range display mode and 'd2' will be ignored.
If 'd2' is set, the scale will only be in dual range display mode and 'd1' will be ignored.
Please refer to Table 1 for division values of 'd1' and 'd2'.
STEP 3: DISPLAY RESOLUTION
'n XXX.XX' will display on screen. The value shown is the display resolution.
Display resolution= (division) kg/ (full cpacity) kg
For dual range display, please refer to Tale 1 for value of 'n'.
Ignore the decimal point shown and take the value as whole number.
Example: tale 'n 060.00' as 6000, take 'n 120.00' as 12000.
Press
to change the value of the selected digit.
Press
to confirm value and enter in to the next step.
Note: Please calibrate the scale again after changing 'Division' and 'Display Resolution' settings.
STEP 4: ZERO RANGE/ZERO TRACKING/WEIGH UNIT SETUP
'Ut ABXY' will display.
A: zero range when power on, 1-9 means 10%-90% FS to zero, 0 mean not to zero
B: Zero tracking range, 1-9 means 1-9 x 0.3d for tracking range
X: Basic unit. It display basic and default unit after indicator is power on.
Y: Second unit. It means you can change unit between Basic unit to Second unit by pressing
Note:
0=kg, 1=lb, 2=oz, 3=HL (Hong Kong use only)
Press
to change basic unit and press
Press
to confirm and enter in to the next step.
until 'CAL SP' display on the screen. Press
to enter menu.

8. CONFIGURATION SETTINGS

to enter into setup mode and 'SET'
to change secondary unit.
User's Guide
.