Installation, use and maintenance

8.2 PERFORMANCE SPECIFICATIONS

FOREWORD
Below is a table with the performance of the unit, measured under optimal conditions (see reference points). The oil
considered for the measurements is of the type SAE 10 W40 at 24 °C
PROBE
Int. Diam. 3 mm
Int. Diam. 6 mm
Int. Diam. 6 mm
ATTENTION
SUCTION HOSE
Maximum length: 10 metres
Diameter: 1/2"
Probe Ø6 mm
9

OPERATING CONDITIONS

9.1 ENVIRONMENTAL CONDITIONS

TEMPERATURE
RELATIVE HUMIDITY
ATTENTION

9.2 ELECTRICAL POWER SUPPLY

NOTE
ATTENTION

9.3 WORKING CYCLE

NOTE

9.4 PERMITTED AND NON-PERMITTED FLUIDS

PERMITTED
The unit can be used to transfer:
FLUDS
- lubricant oil for motors, - lubricant oil for gearboxes, - diesel oil according to EN590.
NON
- lubricant oil for brakes, - windscreen liquid. - anti-freeze fluid
PERMITTED
ALL THE FLUIDS NOT MENTIONED IN "ADMITTED FLUIDS".
FLUIDS
22 /88
It is important to remember that the performance of the unit depends on the following vari-
ables: - Temperature of the measured fluid; - Fluid type ; - System type
Oil temperature (°C)
60
20
40
To guarantee the performance shown in the table, the system must be set up according
to the following characteristics:
DELIVERY HOSE
Maximum length: 50 metres
Diameter: 3/4"
min. -10 °C / max +40 °C
max. 90%
The temperature limits shown apply to the pump components and must be respected
to avoid possible damage or malfunction. It is understood, nevertheless, that for a given
oil, the real functioning temperature range also depends on the variability of the viscos-
ity of the oil itself with the temperature. Specifically:
• The minimum temperature allowed (-10°C) could cause the viscosity of some oils to greatly
exceed the maximum allowed, with the consequence that the static torque required dur-
ing the starting of the pump would be excessive, risking overload and damage to the pump.
• The maximum temperature allowed (+40°C) could, on the other hand, cause the vis-
cosity of some oils to drop well below the minimum allowed, causing a degradation in
performance with obvious reductions in flow rate as the back pressure increases.
Depending on the model, the pump must be fed by single-phase alternating current whose
nominal values are those indicated in the Table of paragraph 8.1,
The maximum acceptable variations from the electrical parameters are:
Voltage:+/- 5% of the nominal value
Frequency:+/- 2% of the nominal value
Power from lines with values outside the indicated limits can damage the electrical com-
ponents.
The motors are intended for continuous use. Under normal operating conditions they can
function continuously with no limitations
Viscosity (cSt)
Flow rate (l/min)
50
20
40
LEVEL DIFFERENCES
Between pump and suction: from 1.5
to 3 metres max.
Between pump and highest point of
delivery: 7 metres max.
0,5
0,8
1,5
M0229 ML