EcoSalt REDOX System Maintenance

MAINTENANCE OF THE POWER SUPPLY:
IMPORTANT: If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Little or no maintenance is normally required with the exception of replacing blown Fuses. These Fuses can
be sourced from your
supply is installed be sprayed (not the unit itself) periodically with a good surface type insect repellent, since
penetration by insects may cause damage, which is not covered by your warranty.
IMPORTANT: Your EcoSalt REDOX should be calibrated regularly following the Setting and
Operating Instructions on page 8, to ensure the desired level of chlorine is maintained.
NOTE: The back of the Power Supply has been designed as a heat sink. It is normal for this area to become
very hot.
MAINTENANCE OF THE IN-LINE ELECTROLYTIC CELL:
The cell is composed of precious materials, and although proper maintenance can prolong its life to the
maximum, eventually the process of electrolysis will wear away its delicate coating, at which time it
gradually ceases to produce chlorine.
Mineral salts and calcium (scale) are deposited on the outer and the inner plates as electrolysis takes
place. This build-up will interfere with the flow of electrical current in the Cell and thus lowers sanitiser
production. It is essential to inspect the Cell regularly and clean when necessary. The rate at which
deposits will form on the plates differs with each pool and can be influenced by the following:
Calcium hardness of the water
¥
Water Temperature
¥
pH level
¥
¥
Water which has been chlorinated with calcium hypochlorite for an extended period
Calcium in the plaster surfaces of a concrete pool
¥
Because these conditions vary so much, check the Cell at least weekly to begin with to see when either
scale or a blue/green soapy substance appears on the plate. You will then be able to determine the
cleaning cycle necessary for your pool (more frequent cleaning may be required in summer). The intervals
between cleaning could get longer to the point where cleaning is only necessary a couple of times each
year. One exception is the use of bore water or ground water, in which case cleaning may always need to
be as frequent as once a week.
NOTE:
In areas with hard water, reverse polarity systems may require occasional manual cleaning.
The life of EcoSalt REDOX electrolytic cells vary substantially from one installation to another due to
variations in operating time, water quality and composition, system and cell maintenance. Please
ensure that when cell replacement is necessary you use the correct genuine EcoSalt replacement cell
to match your system. The correct EcoSalt replacement cell to use is shown in the table below:
EcoSalt REDOX: Reverse Polarity Cell
Model
MC12ORP
ALWAYS INSIST ON GENUINE ECOSALT REPLACEMENT PARTS. If it is necessary to replace the
In-Line Electrolytic Cell, beware of Òlook alikesÓ. Only the Genuine EcoSalt Cell is designed and
warranted to operate with the EcoSalt REDOX Power Supply.
SERIOUS DAMAGE MAY RESULT TO THE ELECTRONICS
USED AND MAY VOID WARRANTY.
!
local Davey Dealer. However it is essential that the wall or post to which the power
Replacement Cell Code
M0696
INSIDE THE UNIT IF COPY CELLS ARE
""!