Adjustment of the automatic close time if enabled by Dip-Switch 1.
Adjustment ranges from 1 sec to max 90 sec
AMP-O
Adjustment of the amperometric sensor obstacle detection sensitivity during the open
cycle.
AMP-C
Adjustment of the amperometric sensor obstacle detection sensitivity during the close
cycle.
Turn the trimmers clockwise (+) to increase the torque, turn them anticlockwise (-) to reduce
the torque.
Adjustment of trimmers AMP-O and AMP-C must comply with statutory regulations.
If an obstacle is detected:
When opening, the gate is stopped.
When closing, the gate stops and opens for about 3 sec.
DIP 1 "TCA"
DIP 2 "COND."
DIP 3
DIP 4 "Radio"
CAUTION! This adjustment strongly affects the safety of the gate automation.
Make sure that the gate thrust complies with statutory regulations.
If the gate speed is changed the amperometric sensor must be calibrated accordingly.
Two faston terminals are provided on the transformer:
Faston F1 (white) regulates the door opening and closing speed and can be preset on three voltage
values:
• 20V: (low speed)
• 28V: (medium speed)
• 35V: (high speed)
Faston F2 (red) must not be moved from 20V position.
The control unit is fitted with a built-in radio module for receiving remote controls both with fixed codes
and variable codes (see dip-switch 4 functions), with a frequency of 433.92MHz.
For a transmitter to be used, the module first has to self-learn its code. The memorise procedure is
illustrated below, the module can memorise up to 64 different codes.
How to memorize a new transmitter code with activation through a P.P. (Step-by-Step) function
-
Press the PGM key once for 1 sec, the DL1 LED starts flashing with 1sec intervals.
-
Within 10 seconds, press the transmitter key to be stored in memory through the P.P. function. After
storage, the receiver automatically exits the programming mode.
To exit the programming mode without storing the transmitter code into memory, wait for 10 seconds.
Remote learning of a transmitter code (rolling-code only)
If a transmitter code is already memorised, other codes can be stored without accessing the control unit.
The remote storage must be carried out with totally open door, regardless of the TCA setting.
Trimmer functions
Dip-Switch functions
Enables or disables automatic closing.
Off: automatic closing disabled
On: automatic closing enabled
Enables or disables the high traffic function.
Off: High traffic function disabled.
On: High traffic function enabled. The P.P. (Step-by-step) or transmitter signal is
ignored during the open cycle and the TCA cycle (if enabled).
Not used.
Enables or disables transmitters with programmable codes
On: Radio receiver enabled exclusively for rolling-code transmitters.
Off: Receiver enabled for both rolling-code and programmable transmitters
(self-learn and dip-switch) .
Motor speed adjustment
Configuration with built-in receiver
11