TECHNICAL DATA

Contol unit supply
Power supply
Output supply
Power maximum motor
Output supply accessories
Protection level
Operating temp.
Radio receiver
Terminals
Function
(1-2)
Antenna
5
COM
6
Step by Step
7
STOP
8
PHOT
24VDC Motor
JP1/JP7
Encoder
14-15
Blinker
16-17
24 Vac
JP4
Secondary
J3
Radio Receiver
N.B.: To control the automation during installation, the Step by Step button on the control unit can be
used.
10
24 Vdc
230 Vac 50/60 Hz
1 motor 24Vdc
120 W
24Vdc 1 A max.
IP54
-20°C / +70°C
The control unit is fitted with a built-in radio module for receiving remote
controls both with fixed codes and variable codes with a frequency of
433.92MHz.
Control units CP.J3M
INPUT/OUTPUT FUNCTIONS
Description
Optional antenna connection to built-in radio receiver board (1-
signal/2-screen).
If external antenna connected cut wire welded to "ANT".
Common for all control inputs.
Step by step button input (N.O. contact)
STOP button input (N.C. contact)
Input for safety devices, N.C. contact (e.g. photocells)
In close cycle: if the contact opens, the motor will stop and will in-
stantly reverse direction (opening).
In open cycle: disabled.
IExtractable connector with connection to 24VDC + Encoder
A: + Encoder
B: S Encoder signal
C: - Encoder
Blinker connection, 24Vac/15W max.
Accessory power supply 24Vac/1A max.
IMPORTANT: If the battery charger board JM.CB is installed, the
output (without mains power connected) has a 24Vdc polarised
voltage. Make sure the devices are correctly connected.
(i.e. 16:+24Vdc - 17:-24Vdc).
Secondary circuit of the transformer.
18 Grey: 0V output
19 Red: Slowdown speed.
Connect the Faston to the 20V output
20 Brown: 24V output
21 White: Motor speed.
See section "Motor speed adjustment "
Built-in radio receiver