Only use the electrode cables
■
supplied by Compex.
Do not disconnect the stimulator
■
electrode cables during the session
without first switching off the
stimulator.
Never connect stimulation cables
■
to an external electric power supply
because of risk of electric shock.
No not use rechargeable batteries
■
other than the one supplied by
Compex.
Never recharge the stimulator when
■
cables and electrodes are still connec-
ted onto the user.
Never recharge the batteries with
■
another charger than the one supplied
with the Compex.
Never use the Compex or the
■
charger if it is damaged (case, cables,
etc.) or if the compartment for the
rechargeable battery is open. There is
a risk of electric discharge.
Disconnect immediately the charger
■
if the Compex "bleeps" continuously,
in case of abnormal heating or smell,
or if smoke comes from the charger
or the Compex. Do not recharge the
batteries in a confined area (case,
etc.) because of risk of fire or electric
discharge.
Keep the Compex and its accessories
■
out of the reach of children.
Do not allow any foreign items
■
(soil, water, metal, etc.) to enter into
the Compex, the compartment for the
rechargeable battery and the charger.
Sudden temperature variations can
■
create droplets in the device due to
condensation. Use the device only
once it reached ambient temperature.
Do not use the Compex while
■
driving or operating machinery.
Do not use the stimulator in the
■
mountains at an altitude higher than
3.000 metres.
90
Where you should never apply
electrodes and the motor point
pen...
To the head.
■
Counter-laterally: do not use the
■
two poles of the same channel (one
electrode connected to the positive/
red pole and one electrode connected
to the negative/black pole) on either
side of the body centreline (eg: right
arm and left arm).
To or in the vicinity of skin lesions
■
of any kind (wounds, inflammations,
burns, irritations, eczema, etc.).
Precautions when using
the
m-4 system
m
To access the
■
Compex, the special electrode cable
m-4
of the
system must be
connected before the device is
switched on.
Avoid connecting the special
■
electrode cable of the
system when the Compex is switched
on.
Do not disconnect the special
■
electrode cable of the
system before switching off the device.
To work correctly, the
■
system must not be blocked or
subjected to pressure.
Precautions when using the
electrodes and the motor
point pen...
Only use the electrodes/the pen
■
supplied by Compex. Other electrodes/
pens may have electrical properties
that are unsuitable for the Compex
stimulator.
Do not remove or move the
■
electrodes during a stimulation session
without first switching off the instrument.
Do not plunge the electrodes/the
■
pen into water.
Do not apply a solvent of any kind
■
to the electrodes/the pen.
functions of the
m-4
m-4
m-4