Appendix
Anhang
Additional UL requirements
1.
Installation
For a complete safe and vault installation connect to 'high security cable'. This
product shall be installed in accordance with The Canadian Electrical Code, Part 1,
Safety Standard for Electrical Installations.
2.
Programming - Sensitivity
Remote input (terminal 7) must not be able to be activated manually. It has to
be assured that remote input is only active while functional noise requires its
activation.
Remote input must not be activated permanently and is limited to 60 seconds.
2.1.
Sensitivity settings verified by UL for Monolithic Concrete:
Minimum
Maximum
thickness
spacing
2.5m
8.2ft
0.6m
1.98ft
4.0m
13.2ft
5.0m
16.5ft
For coverage of surfaces over corners, the recommended spacing is reduced
by 75%.
2.2.
Sensitivity settings verified by UL for Modular Steel Panels:
Minimum
Maximum
thickness
spacing
1.0m
0.006m
0.25in
1.5m
2.0m
A detector shall be on each modular wall panel that is not continuously welded.
For coverage of surfaces over corners, the recommended spacing is reduced
by 75%.
2.3.
Sensitivity settings verified by UL for Steel Safes:
Minimum
Placement
thickness
Body
0.006m
0.25in
Door
Body
0.006m
0.25in
Door
Body
0.006m
0.25in
Door
At least one detector is to be mounted on the door and at least one detector is
to be mounted on the body.
* Note: Shock sensitivity is defined as the sensitivity to single impacts on the detector
or its base. Only in USER MODE, the shock sensitivity can be set independently of
Mode and Operating radius with the help of the GMSW7 SensTool software. If one of
the fixed DIP setting is used, the shock sensitivity corresponds to Mode and
Operating radius as indicated in the tables above.
Requisiti supplementari dell'IMQ
Omologazione IMQ CA12.00766
1.
Specifiche tecniche
Livello di prestazione
Temperatura di funzionato
Grado di protezione
l'assorbimento di corrente
immunità ai campi elettromagnetici10V/m−0.08
Accessori non sono coperti dalla certificazione:
set da incasso
scatola da pavimento
scatola impermeabile
Emisor de ensayo
Generador externo de test
2.
Accessori
Disposizione di prova GMXS1
Piastra copritoppa GMXP3 GMXP3Z
008321_o
Annexe
Appendice
Mode and
Shock
operating radius
sensitivity *
Concrete 2.5m
High
Concrete 4m
High
Concrete 5m
High
Mode and
Shock
operating radius
Sensitivity*
Steel
3.3ft
Low
1m
Steel
4.9ft
Mid
1.5m
Steel
6.6ft
Mid
2m
Mode and
Shock
Maximum
operating
sensitivity*
spacing
radius
Steel
1.0m 3.3ft
Low
1m
Steel
1.5m 4.9ft
Mid
1.5m
Steel
2.0m 6.6ft
Mid
2m
II° livello
+5 ºC fino a +40 ºC
IP30
4 mA
2 GHz
GMXW0
GMXB0
GMXWG0H
GMXS1
GMXS5
I° livello
I° livello
附件 [附件]
Anexo
Exigences supplémentaires de NF&A2P
1.
Fixation
Toutes les exigences relatives aux agréments nationaux et concernant l'application
du produit doivent être satisfaites.
2.
Câblage du détecteur
Le câblage peut être réalisé avec du câble souple de 0,22mm ou du câble de type
SYT.
3.
Accessoires
GMXD7 Feuille anti-perçage
Cette option n'est pas disponible en France.
GMXW0 Jeu pour encastrement mural avec couvercle
mode de protection selon (EN 60529)
capabilité max. de porter du couvercle
GMXB0 Boite de sol
mode de protection selon (EN 60529)
capabilité max. de porter du couvercle
4.
Caractéristiques techniques
Tension d'alim: 8,0 Vcc ....... 16 Vcc; ondulation résidu..: 0,25 Vac
Bande de fréquences :........................................13 à 19 KHz
protection du boîtier (EN 60529, EN 50102) ...............IP43, IK07
5.
Certificat NF&A2P 3 boucliers N° 2730000350A0
Référentiel NF324-H58
GM730
GMXS1
GMXP0
GMXW0
GMXB0
GMXC2
GMSW7
6.
Organisme certificateur :
CNPP Cert.: www.cnpp.com
AFNOR Certification: www.afnor.org
Zusätzliche Anforderungen von VdS
1.
Anwendung
1.
Das Gerät eignet sich zum Einsatz in Einbruchmeldeanlagen nach
DIN EN 50131-1.
Die Einstellposition „Digitaler Filter" in der Betriebssoftware SensTool darf nicht
2.
verändert werden. Werkseinstellung: OFF
2.
Programmierung
Wird der Steuereingang Klemme 7 "Remote" zur Empfindlichkeitsreduktion benutzt,
so muss die Übereinstimmung mit den einschlägigen VdS-Vorschriften im
Systemzusammenhang geprüft, bzw. vom VdS akzeptiert werden.
20
IP51
25 kg
IP51
1000 kg
273035-00
302302-02
302302-03
302302-08
302302-09
303303-02
273034-06