Wire Routing
Vertical Discharge Wire Routing
Horizontal Discharge Wire Routing
Installation Instructions
Route wires here
Route wires here
Figure 21: Vertical Discharge
Route wires here
Figure 22: Horizontal Discharge
Blower Motor Installation
Blower
SKU
Voltage Current
Remote VTR1330
a
120
Inline
120
a
VTI1010
Integral VTN1090
120
a
a
Indicates a letter designating the release year.
Table 3: Blower & Circuit Breaker Ratings
WARNING
Cutting the plug of the blower will void the warranty or
eligibility for return or exchange.
CAUTION
To reduce the risk of fire and electric shock, install this
range hood only with the blowers listed in the Ventilation
Planning Guide.
All hoods require the choice of a Remote, Inline, or Integral
Blower. Use only THERMADOR
THERMADOR ventilation hoods. All blower models are
sold separately. See the Ventilation Planning Guide for
recommended blowers. Contact Customer Service for
additional options.
The hood is rated for 120 VAC, using a 20 amp circuit
breaker.
Blower selection will vary based on the volume of air that
needs to be moved and the length and location of the duct
run. For long duct runs with multiple turns and bends,
consider using a more powerful blower. For the most
efficient air- ow exhaust, use a straight run or as few
elbows as possible (refer to "Ductwork Preparation" on
page 8).
Circuit Breaker
8.8
20 amp
5.7
20 amp
5.4
20 amp
®
blowers with
English | 16 |