Astralpool CANCUN Serie Manual Técnico. Puesta En Marcha Y Funcionamiento página 41

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Units
By means of + and – keys we select ºC or ºFt.
When we switch units the system resets y recalculates all the parameters.
Language
By means of the keys + and – we can select the available languages. (Spanish, English,
French, German, Italian and Protuguese)
Parameters
Acces only it there is the technical shortcircuit.
By pressing the
modify its value.
Parameters description
Parameter Description
Dif-Cns
Allowed difference in the water temperatura (sonde
1). It must be equal/major than 0.5ºC and positive
maintaining the water at 1ºC over the setting
temperature.
Cal-Cns
Water callibration temperature. (Sonde 1)
Cal-DF1
Defrost1 callibration temperature 1. (Sonde 2)
Cal-DF2
Defrost calibration temperature 2. (Sonde 3)
Pow-Fail
Delay in starting up
Min-C.On Minimum compressor working time (sec).
Min-C.Off Minimum compressor stopping time (sec).
Init-Def
Defrost initial T.
Fin-Def
Defrost final T
Min-Def
Minimum defrost time (min)
Max-Def
Manimum (min)
Rea-Def
Sutomatic reset time (hours)
Fluxe
Delay for alarm flow since activating the filtering
pump (sec)
No Val T
Delay of the water T stability(min)
Valid T
Valid Water temperature time . (min)
and
we select the parameters to modify and with + and – we
ENGLISH
Initial Value
0.5
0.0
0.0
0.0
5
5
60
-2
4
5
20
1
10
2
60
41