In any case, it is better not to wait until a leak appears, and for this reason, it is
recommended that the equipment be serviced regularly.
Methods for Searching for a Gas Leak:
There are various tools on the market used in order to detect leaks, although not all of them
are sufficiently sensitive to certain types of refrigerants. It is very important to choose an adequate
detector for the refrigerant used for this equipment and that the maintenance guidelines by
followed.
You can also use soap bubbles (liquid detergent in a spray bottle) to detect leaks.
Other methods such as halogen lighters and additives may also be used to detect leaks.
The R-407-C Gas:
The R-407-C is NOT AN INFLAMMALBE gas; it has no flash point, and so is not
subjected to the rules and regulations of the transportation of inflammable gases.
The R-407-C does not irritate the skin, eyes or mucous membranes and does not produce
and side-effects.
It has a very low level of toxicity for one or many repeated exposures; it does not cause
cancer or mutations.
The R-407-C is susceptible may cause freezing if it comes into contact with the skin, due to
its immediate evaporation.
As with all hydrocarbons, whether they are halogenated or not, the R-407-C gas may,
although it has a very low level of toxicity, cause anaesthetic or preanaesthetic conditions if
inhaled deeply and within a closed area.
19. WARRANTY AND GENERAL CONDITIONS
The manufacturer guarantees the quality of the equipment specified in the LETTER OF
WARRANTY which should accompany this technical manual for start-up and other procedures.
The manufacturer's warranty does not cover breakage or damage resulting from the
following circumstances:
-Inadequate use or installation.
-Failure to follow the cleaning and maintenance instructions.
-Inappropriate chemical conditions.
-Operations done by unqualified personnel.
-Damage caused by inadequate risks.
-Damage caused by natural disasters.
WARNING: in the case that the equipment will be shutdown for a long period of time, we
recommend you remove the equipment or periodically ventilate the area where the equipment is
located. This is because the humid and often corrosive (chlorinated) areas where the equipment is
located may lead to premature deterioration of the electrical components. The warranty does not
cover damage due to prolonged exposure to humid and corrosive atmospheres.
ENGLISH