Aux
Alarms
It indicates the activated alarms. By entering in this menu we can reset the defrost and
start/stop alarms pressing
If there is a grave alarm the red led lights and warns. Alarm meanings:
o X
o T/P
o E
o S
o R
o D
o F
o LEDS
Green led:
Green Led blinking:
green Led off:
Red Led on:
MAIN SCREEN
Display maintains light on during 20 sec since it was pressed the last key. If Stop mode it is just 5
sec.
Heat Pump status
Selected Mode
As the water T is measured in the pump, it is necessary that the water floes during a period of time
to obtain a good reading. So, in CONFORT amd PROGRAM modes, the filtering puma will be
activated periodically to obtain a good reading.
If is 0 just take into account DF1 (Sonde 2), and if
is 1 considers both sondes.
if they are activated.
Electric supply failure. Error in the RST phases order. Screen will
show AC FAIL. This alarm rests automatically.
Pressure switch alarm. The machine stops and rests after 20 minutes.
It continues reseting
problem persists it appears PR STOP so manual reset it is needed
(press the
Error sonde 1 (water temperature) It rearms automatically.
Error sonde 2 (defrost temperature 1) It rearms automatically.
Error sonde 3 (defrost temperature 2) It rearms automatically
Defrost error (time exceeded) (See defrost chapter).
Flow error. It rearms automatically
Heating. Normal process
Doing some function until reach the normal process (For
instance, defrost)
No supply, stopped or activated alarm.
Alarm activated. System off.
automatically 3 times in 24 hours. If the
in the alarm menu).
Water Temperature
0
Date and time
ENGLISH
42