(1) Thick black cable
(2) Battery case
(3) Earth cable
(1) Plug
A Connect the charger positive terminal to the battery
positive terminal, and negative to the negative.
A When disconnecting the cable from the battery, start
with the negative terminal first.
When connecting the cable to the battery, start with
the positive terminal first.
If reversed, the contact of tools on the battery may
cause a short.
BDirection for long term storage
1. When storing the engine for long periods of time,
remove the battery, adjust the electrolyte to the proper
level, and store in a dry and dark place.
2. The battery naturally discharges while it is stored.
Recharge it once a month in summer, and every 2
months in winter.
(A) "HIGHEST LEVEL"
(B) "LOWEST LEVEL"
PERIODIC SERVICE
ELECTRIC WIRING
To avoid personal injury:
C Shorting of electric cable or wiring
may cause a fire.
A Check to see if electric cables and
wiring are swollen, hardened or
cracked.
A Keep dust and water away from all
power connections.
Loose wiring terminal parts, make
bad connections. Be sure to repair
them before starting the engine.
Damaged wiring reduces the capacity of electrical parts.
Change or repair damaged wiring immediately.
1. Use automobile low voltage wiring cables for this
wiring harness.
2. Use fuse and slow blow fuse as wiring protection.
3. Generally, available current of each fuse and size of
wire in this drawing are recommendable value showed
by Kubota, use suitable size fuses and wires for each
machine to consideration to wiring setting and
connection with another lines.
4. Install slow blow fuse near by battery, and install fuse
box near by key switch.
5. Do not connect any parts which may cause induction
current like motors to AC line.
6. Use heatproof cables, if room temperature around
wire harness become over 75
7. Remove painting at connecting position before
installation of each cable to any parts.
21