Boiler Running; Run Mode; Water Temperature Adjustement; Working Power Adjustement - Bio Bronpi HYDROBOX Instrucciones De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

9.7.2.

BOILER RUNNING

Once smokes temperature reach the set up the boiler considers it is working, then will switch to "stabilization" during a few minutes before
ending the lighting process.
Once the stabilization process is finalized the boiler is in mode "Run mode" represented by the normal working mode. The display will show
the time, date, working power, water temperature, thermostat temperature and winter/summer mode.
9.7.3.

WATER TEMPERATURE ADJUSTEMENT

This function is only available inside the user menu. Check the chapter 9.8.2.1.
9.7.4.

WORKING POWER ADJUSTEMENT

This function is only available inside the user menu. Check the chapter 9.8.1.1.
9.7.5.

ROOM TEMPERATURE REACHES THE REQUESTED VALUE BU THE USER

When room temperature reaches the requested value by the user, the boiler receives the order through an external thermostat connected
to the boiler and automatically start the switch of process, and will switch on automatically when room temperature in under the consigned
temperature. This depends on the thermostat hysteresis installed in your house.
9.7.6.

WATER THERMOSTAT REACHES THE REQUESTED VALUE BU THE USER

When the water temperature of the boiler reaches the requested value by the user, the boiler start mode "stand by", i.e. starts modulation
lowing the power to adequate to the selected temperature of the water and keep on working. In this case it is possible that your house do not
reach the temperature requested from the external thermostat because the water temperature value that you have fixed is low for your comfort
temperature. We recommend putting an enough temperature value (70-75º) to allow the boiler keep on working and reach your house comfort
temperature.
9.7.7.

CLEANING THE BURNER

During the standard working of the boiler automatic cleaning processes are appearing
periodically. The cleaning remains during a few seconds and it consists on cleaning the
rest of pellet in the burner, blowing (increasing the exhaust fan speed) and therefore help
the proper function of the boiler. During this process the display will show the following
message:
In the Hydroconfort model, the burner has an automatic ash cleaning system, in addition
to blower burner cleaning. The burner has a cleaning system that periodically sends the
ashes that are generated in the combustion to the ashtray (Cleaning system patented by
Bronpi Calefacción S.L) which consists of rotating the base of the burner and brush it.
9.7.8.

BOILER SWITCH OFF

To switch off the boiler we have to push the key
start the end cleaning process where the auger stop and the smoke extractor works at maximum power. This process will not finish until the
boiler has reached the proper cooled temperature.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
11:24
Wed 11 September
21º
Stabiliz
2
1
11:24
Wed 11 September
21º

Run Mode

2
1
during three seconds. Then the boiler
54
Crono
Disabled
Er.01
65º C
Crono
Disabled
Er.01
65º C
11:24
Wed 11 September
21º
Cleaning On
HYDROBOX, HYDROTEX AND HYDROCONFORT
Crono
Disabled
Er.01
65º C
2
1

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

HydrotexHydroconfort

Tabla de contenido