11:24
To unlock the boiler, you must press the
Note: There are alarms that require the intervention of the Technical Assistance Service to be unblocked.
9.8.
END USER MENU 1
To access user menu1 it is necessary push only once the key
Next board describes briefly the structure of the user menu 1 in the boiler. The available options are specified.
To select between different menus we will have to push each line and will access to different available submenus. To modify the values we
have the keys
and
to increase and decrease and confirmation key
to the main screen, or increase one menu level by pushing the key
9.8.1.
MENU 1. COMBUSTION MANAGE
This menu manages the combustion parameters. It has different submenus:
9.8.1.1.
POWER
You can modify the power of the boiler according to different set ups: Power 1, 2, 3, 4, 5 or A
(A=Automatic combustión). The selected value should be confirmed with the key
going out of the menu.
9.8.1.2.
AUGER CALIBRATION
You can increase or decrease the fixed value with the keys
factory is 0 and the range is between -7 to +7. Consider that each value you modify is
equivalent to modify proportionally 2% each power the value of loading time (seconds)
assigned to the auger motor. The selected value should be confirmed with the key
going out of the menu.
Consider that as more pellets we load the more power the boiler provides and more
consume of combustible. In case you see the stove does not burn properly or the mix
combustible/air is not the right one try with this loading parameter.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
Crono
Wed 11 September
Disabled
21º
Er.01
Er 05
2
1
(red) button for 3 seconds and then you will be able again to proceed with the ignition of the boiler.
Menu
Combustion manage
Heating manage
Puffer tank thermostat Value between 40 y 55ºC
Remote control
Chrono
Manual auger load
11:24
Wed 11 September
65º C
Block
in the display.
. To exit from the menu it is necessary to push the key
.
Submenu 1
Power
1, 2,3, 4, 5 y A
Auger calibration
Value between -7 y +7
Fan calibration
Value between -7 y +7
Boiler thermostat
Value between 40 y 80ºC
Summer / Winter
Summer / Winter
On/Off
Chrono ON
Diary ON
Week ON
Weekend ON
On/Off
before
or
. The fixed value from
before
56
Crono
Disabled
21º
Er.01
65º C
2
1
Submenu 2
Power 1
Power 2
Power 3
Power 4
Power 5
Settings
Auger Calibration
0
Min: -7 Max: 7
HYDROBOX, HYDROTEX AND HYDROCONFORT
and go