CHARGING PROGRAM, LI-ION
WAKE UP
2.0A pulse
Push MODE button
Time limits
for 10s
WAKE UP
Push MODE button for 10s for activating the UVP, see "Errors and solutions".
ACCEPT
Tests if the battery can accept charge. This step prevents that charging proceeds with
a defect battery.
BULK
Charging with maximum current until approximately 90% battery capacity.
ABSORPTION
Charging with declining current to maximize up to 100% battery capacity.
20020455B Porsche 60W Charge-o-Mat PRO, Manual 1 EU, Print file 001.indd 13
ACCEPT
BULK
Li-Ion
5.0A until 11.0V
Increasing voltage to
13.6V.
5.0A
Max 30s, auto start
Max 15h
ABSORPTION
ANALYSE
Li-Ion
Li-Ion
Declining current.
Checks if voltage drops
13.6V
to 12V
Max 10h
3 min
ANALYSE
Tests if the battery can hold charge. Batteries that can not hold charge may need to
be replaced.
FLOAT
Maintaining the battery voltage at maximum level by providing a constant voltage
charge.
PULSE
Maintaining the battery at 95–100% capacity. The charger monitors the battery
voltage and gives a pulse when necessary to keep the battery fully charged.
FLOAT
PULSE
Li-Ion
13.5V.
13.4–13.6V
5.0A
5.0–1.0A
Charge cycle restarts
24h
if voltage drops.
EN • 13
2014-06-26 14:38:36