Installation
Configure the system - Variable table
Nr.
Name
Par.
111
Digital Input Setup
112
Analog Input Setup
123
Board serial number
124
Slave type
Right Access (see paragraph
125
"Access Level")
126
User Interface Connected Address
127
Board address
128
User Interface self Address
Description
Use Days button to select the sub-parameters.
Input values.
Use HOLD to quickly switch between plus and minus
PIN 22 - Input 1
Select input code
PIN 20 - Input 2
Select input code
PIN 12 - Input 3
Select input code
PIN 21 - Input 4
Select input code
PIN 13 - Input 5
Select input code
PIN 14 - Input 6
Select input code
PIN 20-21 - Input 7
Select input code
Use Days button to select the subparameters
Water from Comfort Module entering in pool
exchange
0. Not connected
1. Connected
Leaving Water Temperature to the pool
0. Not connected
1. Connected
Water Pool temperature
0. Not connected
1. Connected
Network configuration
Display the serial number.
For User Interface is showed only the following digits
underlined:
XxxXxXXXXX
Define the slave board type:
1: Zone kit
2: Pool kit (only one in the network)
Right access:
0: Access level 0
1: Access level 1
2: Access level 2
3: Access level 3
User Interface address associated to the relevant Board
(at Par. 127) and Zone (Par. 22)
0. No User Interface connected
Address of the board which Variable Table is shown
Shows the address of the User Interface being used
RANGE
MIN
MAX DEFAULT
-12
12
0
0
1
0
-
-
-
1
2
2
0
3
1
85
213
0
Own
0
255
address
Own
85
213
address
4
80HMA - 9002