lower part of the gauge.
Once the adjustment operation has been com-
pleted, screw the protective metal sheet back
into its setting and replace the worktop grid
cover.
5.3
HOT WATER
ECONOMISER
ADJUSTMENT
(optional V / S model)
All
models are equipped with a hot
water mixer that allows the regulation of the
outlet temperature of the water and to optimise
the performance of the system.
To adjust the hot water economiser, adjust the
screw positioned to the left in the upper panel
as shown in Fig. 18.
Utilising a flat blade screwdriver, turn in a clock-
wise direction to increase the temperature and
in an anticlockwise direction to lower the tem-
perature.
_
Fig. 17
5.4
For correct functioning of the machine, person-
alising each button panel card at time of
replacement is necessary; proceed as follows
on the selectors placed on the card (on the key
side).
GROUP sw1 sw2 sw3 sw4 sw5 sw6
+
Group 1
Group 2
Group 3
Fig. 18
PUSH-BUTTON PANEL
REPLACEMENT
On Off Off On Off Off
Off On Off Off On Off
Off Off On Off Off On