1) GENERAL OUTLINE
The SP4000 - SP4000 FAST controller consists of a strong gearmotor. The
motor/reduction gear is an hydrodynamic coupling tipe that allows the gate
leaf to start and stop smoothly, in order to avoid high structural stress. The
self-braking motor allows the leaf to stop rapidly avoiding uncontrollable
inertial sliding movements.
The gearmotor is joined to the gate by means of a rack. The control panel is
incorporated and comprises: protection fuses, three-phase overload cutout
and control unit.
The function logic allows various configurations to be set in order to bet-
ter adapt the automation to the customer's needs (e.g.: automatic closing,
photocells activated on closing, etc.). To change any settings, contact a
qualified technician (installer).
The irreversible type gearmotor keeps the leaf locked on closing. This way
it does not need an electric lock.
A manual release system allows the leaf to be opened manually in case of
power supply disconnection or inefficiency.
The installation must be provided with all the devices needed to guarantee
safety of persons, animals and things, according to the provisions set out
by the current standards.
2) SAFETY
If correctly installed and used, this automation device satisfies the required
safety standards.
However, it is advisable to observe some practical rules in order to avoid
accidental problems.
Before using the automation device, carefully read the operation instructions
and keep them for future reference.
• Keep children, persons and things outside the automation working area,
particularly during operation.
• Keep radio control or other control devices out of children's reach, in order
to avoid any unintentional automation activation.
• Do not intentionally oppose the leaf movement.
• Do not attempt to open the gate manually before to have released the
motor by mean of the appropriate key.
• Do not modify the automation components.
• In case of malfunction, disconnect the power supply, activate the emer-
gency release in order to be able to open the gate manually and request
the assistance of a qualified technician.
• Before proceeding to any outside cleaning operation, disconnect
the mains powers supply.
• Keep the sliding guide of the gate, photocell optical components and light
signal devices clean. Check that the safety devices (photocells) are not
obscured by branches or shrubs.
• Check the rack lubrication periodically.
• For any direct assistance to the automation system, request the help
of a qualified technician (installer).
• Have qualified personnel checking the automation system once a year.
3) EMERGENCY MANOEUvRE
When the electric supply is disconnected or the automation is faulty, the leaf
must be opened manually.
3.1) Activation
• Open the front actuator door using the key provided (fig.1).
• At the time of opening, a safety microswitch stops the actuator from
operating electrically.
• Take out the release key (fig.2 ref. "C") located inside the box and insert
it in the release screw (fig.2 ref. "V") .
• Turn the key (fig.2 ref. "C") anticlockwise until the pinion drive system
becomes completely loosen.
• This way, the pinion is released and the gate can be operated manually.
WARNING - Considering the leaf weight, it is recommended to guide the
leaf manually along the entire run, and absolutely avoid to push it in an
uncontrolled way.
4 -
SP4000 - SP4000 FAST - Ver. 05
USER'S MANUAL
3.2) Re-activation
• Open the actuator door with the appropriate key.
• Insert the release key (fig.2 ref. "C") in the release screw (fig.2 ref. "V")
and turn it clockwise until it is completely tightened.
• Put release key "C" back in its place, close the actuator door and check
that the automation operates electrically.
• Put the actuator door key away in a safe place known to the operators.
4) MAINTENANCE AND DEMOLITION
The maintenance of the system should only be carried out by qualified
personnel regularly. The materials making up the set and its packing must
be disposed of according to the regulations in force.
Batteries must be properly disposed of.
WARNINGS
Correct controller operation is only ensured when the data contained
in the present manual are observed. The company is not to be held
responsible for any damage resulting from failure to observe the
installation standards and the instructions contained in the present
manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
C
C
Fig. 1
Fig. 2
v