ENGLISH
Thank you for buying this product, our company is sure that you will
be more than satisfied with the product's performance. The product
is supplied with a "Warnings" leaflet and an "Instruction booklet".
These should both be read carefully as they provide important infor-
mation about safety, installation, operation and maintenance. This
product complies with the recognised technical standards and safety
regulations. We declare that this product is in conformity with the fol-
lowing European Directives: 89/336/EEC, 73/23/EEC, 98/37/EEC (and
subsequent amendments).
1) GENERAL OUTLINE
The DEIMOS BT-MA actuator offers ample installation versatility thanks
to its compactness, the extremely low position of its pinion as well as the
height and depth adjustments available. The adjustable electronic torque
limiter ensures antisquash safety. The emergency manual manoeuvre
can be activated very easily by means of a knob. The end-of-run stop
is controlled by electromechanical limit microswitches. The control unit
is incorporated. Before each manoeuvre, the control unit performs a
check of the operation relays and safety devices (photocells, rubber
skirt, etc.).
The gearmotor (fig.1) comprises:
The incorporated control panel checks the drive relays and safety devices
(photocells and safety edge) before carrying out any manoeuvre.
M
Motor.
R
Reduction gear with worm screw and wheel.
F
Electromechanical limit switch unit.
P
Pinion.
S
Release mechanism.
NETTUNO S
Control panel
The following optional accessories are available:
- SBBAT mod. Buffer battery kit
It can be incorporated into the actuator and allows the automation system
to operate even when the mains power supply is disconnected for a short
time. The pack includes (fig.1):
• 2 buffer batteries (ref. B).
• 1 battery holder base (ref. BB).
• 1 battery charger board (ref. SBS).
• Assembly instruction manual.
• Various bolts, screws and cables.
- MSC mod. Release knob (fig.18)
Fixed release knob with personalised key.
The NETTUNO S control board manages the innovative FAST NET wiring
system.
The FAST NET system allows to connect all the accessories necessary for
the automation of a gate with only 2 ducts. All accessories are connected
in parallel on the same non-polarised telephone-type paired wire through
which the current necessary for powering both the devices and the infor-
mation communication is transmitted. After setting the correct configuration
(paragraph 15.6) each device connected to the FAST NET net is recognized
and identified by giving it an address. If the number of devices connected
to the FAST NET net changes (by adding or eliminating some of them) the
configuration procedure (paragraph 15.6) should be repeated. Up to 16 FAST
NET devices can be connected to the NETTUNO S control board. To connect
a large number of devices more easily, it is possible to connect some of them
between the terminals 12-13 and some others between the terminals 14-15
provided that no more than 16 devices max. are connected. The devices are
subdivided into categories and a maximum number of devices that can be
connected for each category is envisaged (Table 1) but limited to a total of
16 max. that should never be exceeded. Some devices can take 2 addresses
(as if they were 2) and therefore it is recommended to check the number of
addresses occupied by each device on table 2.
Table 1
Device Category
Radio receivers
Blinkers
Control push-buttons
Push-button panel with double
push-button and warning light
Numeric keyboard
16 -
DEIMOS BT - NETTUNO S-MA - Ver. 04
INSTALLATION MANUAL
Max no. of devices that can
be connected
2
4
4 for type (4 start, 4 close...etc)
4
4
Table 2
Device
FL NET TX - Photocell transimitter FL NET
FL NET RX - Photocell receicer FL NET
NET LAMP - Blinker only
NET LAMP - Blinker with integrated radio receiver
SC NET - START only key selector
SC NET - START + PED key selector
SW NET - START + PED button interface
SW NET - START + OPEN + CLOSE button interface
Out of the programming menu, a START command can be given by pressing
the "+" and "OK" keys simultaneously.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product can
cause damage to persons, animals or things.
•
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
•
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
•
Keep the instructions together with the technical brochure for future
reference.
•
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
•
The Company declines all responsibility for any consequences result-
ing from improper use of the product, or use which is different from that
expected and specified in the present documentation.
•
Do not install the product in explosive atmosphere.
•
The construction components of this product must comply with the following
European Directives: 89/336/CEE, 73/23/EEC and subsequent amend-
ments. As for all non-EEC countries, the above-mentioned standards as
well as the current national standards should be respected in order to
achieve a good safety level.
•
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing clos-
ing structures (door, gates etc.), as well as from any deformation which
might occur during use.
•
The installation must comply with the provisions set out by the following
European Directives: 89/336/CEE, 73/23/EEC, 98/37/EEC and subsequent
amendments.
•
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
•
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3,5 mm.
•
Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.
•
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
•
Fit all the safety devices (photocells, electric edges etc.) which are needed to protect
the area from any danger caused by squashing, conveying and shearing.
•
Position at least one luminous signal indication device (blinker) where it
can be easily seen, and fix a Warning sign to the structure.
•
The Company declines all responsibility with respect to the automation safety
and correct operation when other manufacturers' components are used.
•
Only use original parts for any maintenance or repair operation.
•
Do not modify the automation components, unless explicitly authorised
by the company.
•
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
•
Do not allow persons or children to remain in the automation operation area.
•
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
•
The user must avoid any attempt to carry out work or repair on the automa-
tion system, and always request the assistance of qualified personnel.
•
Anything which is not expressly provided for in the present instructions,
is not allowed.
•
Installation must be carried out using the safety devices and controls
prescribed by the EN 12978 Standard.
3) TECHNICAL DATA
3.1) DEIMOS BT-MA Actuator
Power supply: ..................................... single-phase 230V~ ±10% 50Hz (*)
Motor: ............................................................................................. 24V
N.of Occupied
Addresses
1
1
1
2
1
2
2
3