Subtracting count mode
without automatic reset and
batch counter
The batch counter counts the
number of times the main
counter reaches zero
Adding count mode without
automatic reset and totalizer
The totalizer counts all count-
ing pulses of the main counter
Subtracting count mode
without automatic reset and
totalizer
(only for counter with 2 pre-
sets), the totalizer counts (sub-
tracts from Preset 1) all
counting pulses of the main
counter
Multifunction totalizer (for
counters with 1 preset, the
preset is de-activated and the
function has only a display
function). Only input modes
AS [A-B] and AA [A+B] can be
programmed, input A adds the
pulses in counter 1, output 1
active when counter 1 > Pre-
set 1, display indicator PR1
lights .
Input B adds or subtracts the
pulses in counter 2, output 2
active when counter 2 > Pre-
set 2, display indicator PR2
lights.
Counter 3 shows the sum or
the difference of inputs A and
B, display indicators PR1 +
PR2 light.
The Prog/Mode key allows
switching between the coun-
ters 1,2, 3, upper display line =
counter value, lower display
line = preset value. Manual
reset: only for counters 1 and
2, for the displayed counter,
electrical reset: resets all 3
counters simultaneously.
6.8.3.2 Main menu for the signal and
control inputs
Main menu for programming
the signal and control inputs
Input polarity
PnP: switching to Plus
for all inputs in common
nPn: switching to 0 V
for all inputs in common
Filter for the signal inputs
InpA and InpB
Maximum count frequency
Damped to approx. 30 Hz
(for control with mechanical
contacts)
Count input mode
Count/Direction
INP A: count input
INP B: count direction input
Differential counting [A – B]
INP A: count input add
INP B: count input sub
Totalizing [A + B]
INP A: count input add
INP B: count input add
8