7. Strip 6 inches (15cm) of the outer cord jacket from the cord to expose the two insulated wires – be careful not
to damage the insulation on the inner wires.
8. Connect both wires to the corresponding circuit wires in the Junction Box and secure the Junction Box cover
in place.
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submer-
sion, the light assembly will get extremely hot, which may result in serious burns or in breakage of the lamp or lens. This may
result in serious injury to pool users, installers, or bystanders, or in damage to property.
9. Replace light assembly into the niche and tighten the special pilot screw.
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing
securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could
result in death or serious injury to pool users, installers or others due to electrical shock.
10. Fill the pool until the underwater light is completely submerged in water before operating the light for more
than 10 seconds. Turn on main switch or circuit breaker, as well as the switch which operates the underwater
light itself, to check for proper operation. Refer to Operating Instructions, Section IV., for full function test.
Section III. Switching Options for Spectrum Amerlite
A. Multiple SAm lights ALWAYS in color synchronization.
1. If multiple SAm lights are desired to always be on or off together and always with synchronized colors,
multiple SAm lights may be controlled by a single switch to the extent allowed by code and capacity of the
electrical equipment.
B. Multiple SAm lights controlled separately but with color synchronize capabilities.
1. If on/off function or color of multiple SAm lights is desired to be controlled separately, then the SAm lights
should be controlled by separate switches. It is recommended that the switches controlling the SAm lights be
in immediate proximately of each other to allow simple color synchronization.
Section IV. SAm
Operating Instructions
®
A. ON -- SAm turns on whichever color it was turned off.
B. 1
OFF/ON -- SAm fast forwards to white and pauses for up to 30 seconds, waiting for other SAm's to
st
synchronize. SAm then begins rolling through the Spectrum and will continue rolling until receipt of next switch
command.
C. 2
OFF/ON -- SAm holds on displayed color.
nd
D. OFF/ON -- Repeats 1
E. OFF/ON Again -- SAm holds on displayed color.
If multiple SAm lights are preferred in color synchronization, the above should be performed on respective switches simulta-
neously. If they are desired on different colors they should be switched separately.
Rev. B • Rev. B • Rév. B 10-29-07
OFF/ON sequence function.
st
WARNING
WARNING
Color Synchronization
®
NOTE
5
P/N • Núm/Pte. • Réf. P/N 619587