Descargar Imprimir esta página

Goulds Pumps GL Serie Instrucciones De Instalación, Funcionamiento Y Mantenimiento página 12

Publicidad

Idiomas disponibles

Idiomas disponibles

lubricant compatible with the o-ring and install
the new seat by pressing it into the seal housing
with your thumb. DO NOT USE EXCESSIVE
FORCE and, if possible, place a clean soft cloth
over the seal face to protect the seal faces during
installation.
7. Remove the rotary portion at the mechanical seal
by sliding the rotary unit axially upwards along
the pump shaft. Inspect the pump shaft for any
burns or debris. Any burrs should be around
Figure 5
12
smooth with (fi ne grit) emery paper. See step 7 in
Figure 5.
8. Lubricate the o-ring located in the ID of the rotary
unit of the mechanical seal with a lubricant com-
patible with the seal elastomers. Carefully slide the
rotary unit of the mechanical seal down the shaft.
Rotate the seal to locate the pin on the bottom of
the seal with the holes in the shaft sleeve. Cycle seal
up and down to lubricate o-ring and prevent seal
from sticking to shaft. See step 8 in Figure 5.

Publicidad

loading