Raw Water Considerations
■ The Raw Water pump must be securely
mounted in a dry, well-ventilated area. It
should be mounted not more than 6' at any
time above the heeled waterline.
DANGER:
The Raw Water pump
must be powered by the toilet relay mod-
ule. Use of any pump that draws more
than 15 amps requires installation of a
pump contractor relay. Do not wire pump
directly to a D.C. power source so that
it is controlled by its pressure-activated
switch. If a leak were to occur when wired
directly, the pump would run continuously
and create risk of sinking of the boat and
loss of life.
■ An in-line strainer MUST be installed
to protect the system. Failure to use an
in-line strainer may void product warranty.
■ A Vented Loop of proper diameter
MUST be installed if – UNDER ANY
CIRCUMSTANCE or CONDITION
(including heel trim or load):
•
Toilet is connected to a through-the-hull
fi tting and rim of toilet could EVER be in a
position below the waterline.
DANGER:
Failure to use a Vented
Loop in raw water pump installation sites
can lead to water fl owing into the toilet from
the outside (siphoning) which can cause
loss of property and life!
www.thetfordmarine.com
Manuale di Installazione e Istruzioni, cont.
Considerazioni sull'installazione
della pompa dell'acqua non
depurata
■ La pompa dell'acqua non depurata deve
essere montata saldamente in un luogo
asciutto e ben ventilato. Deve essere
montata in un punto a non più di 1,8 m in
qualsiasi momento al di sopra della linea di
galleggiamento inclinata.
PERICOLO:
La pompa dell'acqua
non depurata deve essere alimentata dal
modulo relè toilette. L'utilizzo di qualsiasi
pompa che consuma più di 15 ampere
richiede l'installazione di un contattore
relè pompa. Non collegare direttamente la
pompa a una sorgente di alimentazione CC
in modo che sia sotto il controllo del suo
pressostato. Se una dovesse verifi carsi
una perdita quando cablata direttamente, la
pompa potrebbe funzionare continuamente
e creare rischio di affondamento della barca
e morte.
■ DEVE essere installato un fi ltro di linea per
proteggere il sistema. Il mancato utilizzo di
un fi ltro di linea può invalidare la garanzia
del prodotto.
■ DEVE essere installato un sifone ventilato
del diametro giusto se - SOTTO QUALSIASI
CIRCOSTANZA o CONDIZIONE (comprese
situazioni di sbandamento, di carico o
di stivaggio):
•
La Toilet è connessa a eventuali raccordi
passanti e il bordo della toilette potrebbe
trovarsi SEMPRE sotto la linea di
galleggiamento.
PERICOLO:
Il mancato utilizzo di
un sifone ventilato in luoghi di installazione
della pompa dell'acqua non depurata può
portare a un fl usso dell'acqua nella toilette
dall'esterno (sifonamento) che può causare
la perdita di cose e della vita!
41
Bedienungs- und Einbauanleitung - Forts.
Hinweise für Installationen
mit Seewasserversorgung
■ Die Seewasserpumpe muss in einem
trockenen, gut belüfteten Bereich fest
montiert werden. Die Pumpe ist so
zu installieren, dass sie unter allen
Bedingungen maximal 1,8 m über der
Wasserlinie bei Krängung positioniert ist.
GEFAHR:
Die Seewasserpumpe
muss über das Relaismodul der Toilette
mit Strom versorgt werden. Wenn
die Stromaufnahme der verwendeten
Pumpe mehr als 15 A beträgt, muss ein
Hilfsschützrelais für die Pumpe installiert
werden. Die Pumpe darf nicht direkt mit
einer Gleichstromquelle verdrahtet werden,
um zu verhindern, dass sie durch den
druckaktivierten Schalter gesteuert wird.
Bei direkter Verdrahtung würde die Pumpe
im Falle eines Lecks kontinuierlich laufen,
was zum Sinken des Boots und Verlust von
Menschenleben führen kann.
■ Zum Schutz des Systems MUSS ein
Leitungssieb installiert werden. Die
Nichteinhaltung dieser Anweisung kann
die Produktgarantie nichtig machen.
■ Ein belüftbares Schwanenhalsventil mit
ordnungsgemäßem Durchmesser MUSS
UNTER ALLEN UMSTÄNDEN oder
BEDINGUNGEN (einschließlich Krängung
oder Last) installiert werden, wenn:
•
die Toilette an ein Borddurchlass-
Anschlussstück angeschlossen ist
und die Oberkante der Toilette sich
ZU EINEM BELIEBIGEN ZEITPUNKT
unter der Wasserlinie befi nden kann.
GEFAHR:
Wenn bei Installationen
mit Seewasserpumpe kein belüftbares
Schwanenhalsventil verwendet wird,
kann Wasser (durch Siphonwirkung) von
außen in die Toilette gesaugt werden, was
zu Sachschäden und zum Verlust von
Menschenleben führen kann!