Using your SGA/AXOVIA
I Going from auto mode to normal mode:
In order to return to the sequential mode (the AUTO light is lit) :
• Place the remote control on the target engraved on the hood.
• Push on key of remote control until the AUTO light goes off.
>The normal mode (sequential functioning) is active.
J Securization of parametering
1
Push on the complete opening button
2
Push a second time on the button so that both leaves stop at mid opening
3
Cut off the mains supply 5 seconds
4
Turn back on the mains supply
5
Push on the complete opening button
The leaves MUST start up in the opening direction.
Using your SGA/AXOVIA
I Deleting emitters
1
• Press 7 seconds on reset button.
> While pushing, the four lights turn on.
2
• Release the reset button.
> The four lights go off for 2 seconds
> The ON/OFF light turns back on
> The PROG light turns on
Reset button
All the recorded parameters are deleted : recorded remote control, gate displacement,
functioning mode...
I Subsequent remote control addition
For a subsequent addition of remote controls, redo the following operations :
• Memorization of the remote controls.
• Memorization of gate leaf displacement.
Any new remote control memorization cancels and replaces the
preceding program of gate displacement
Lights