Dipswitches are located behind the round black cap located on the front side of the charger and next
SW1
DP1
Charging current
Charging Termination
ON: half charging
ON: stop charge
current (2,5A)
OFF: maximum char-
ging current (5A)
Default Setting
Default Setting
BATTERY CHARGER
416S
CT15
DP2
DP1
Curve
OFF: IUUO-GEL for
generic GEL and
AGM batteries
ON: IUIa-AGM
at 27,6V
DISCOVER for
DISCOVER AGM
batteries
Default Setting
SW2
DP2
TCL Function
OFF: TCL enabled
ON: TCL disabled
Default Setting
GB
SW1
SW2
DP1
DP2
DP1
DP2
ON
ON
ON
ON
RED
YELLOW
GREEN
OFF
OFF
OFF
OFF
LED
LED
LED
8
ON