MANUAL DE INSTRUCCIONES CODIGO 80184 REV A Jul/2016
9
8
7
2
3
4
1
Pic 6. Connect vacuum hose to
the lid
J
.P. SELECTA s.a.u.
6. OPERATION
CONTROL PANEL:
10
1. Main switch.
2. Temperature/time selection key
11
3. Increase value key
4. Decrease value key
6
5. Time counter start key
6. Vacuum pump start key
7. Time selection indicator led
5
8. Temperature selection indicator led.
9. Display
10. Run pump indicator led
11. Run time indicator led
7. STARTING UP
DO NOT START UP THE EQUIPMENT UNTIL YOU
1. Fill up the pot with the food to cook and the liquid.
2. Check that the gasket and the fi xing hoop are properly adjusted
to the lid. See picture.
3. If the case of frying, attach the basket to the lifting device. See
pictures.
4. Put the lid.
5. Put the pot on the hot plate.
6. Connect the vacuum hose to outlet on the lid. See picture
7. Fit temperature probe into the hole placed on the pot bottom
to cook or to fry (see picture). To do impregnations at room
temperature it is not necessary to connect the probe.
Ctra. NII Km 585.1 Abrera 08630 (Barcelona) España
e-mail: selecta@jpselecta.es - www.jpselecta.es
(Sujetas a modifi caciones sin previo aviso)
ARE GOING TO USE IT
Tel 34 937 700 877 Fax 34 937 702 362
Pag.: 10