Installation
Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 50mm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select
heat-resistant work surface material to avoid larger deformation caused by the
heat radiation from the hotplate. As shown below:
H
D
X
B
L(mm)
W(mm)
590
520
Under any circumstances, make sure the ceramic cooker hob is well ventilated
and the air inlet and outlet are not blocked. Ensure the ceramic cooker hob is in
good work state. As shown below
Note: The safety distance between the hotplate and the cupboard above
the hotplate should be at least 760mm.
D
L
X
H(mm)
D(mm)
55
51
A
B
E
C
W
A
X
A(mm)
560+4
+1
EN-15
X
B(mm)
X(mm)
490 +4
50 mini
+1