START-UP
- Replace the RED transport cap with the cap with a built-in dipstick.
- Check the oil level through the window or using the dipstick and, if necessary, top it up.
- Make sure that all fi ttings are securely tightened and that the pump feed is open.
- To expel the air present in the pump and make it easier to fi ll, we recommend you detach the delivery
pipe from the pump or keep the port/s open without any nozzles fi tted.
- Start the pump for 5/10 seconds until the liquid fl ows out smoothly from the delivery pipe or applian-
ces; if this does not happen, stop the pump and repeat the operation after a 10-second pause.
- Complete the connections and/or install the nozzles.
- Calibrate or regulate the valves; to prevent tampering, apply lead seals where possible, or paint the
regulating registers so that any tampering can be readily detected.
- All INTERPUMP pumps are tried and tested prior to shipment, the installation engineer is, however,
obliged to test the complete system for an adequate time to check for leaks, overheating, deterioration
in performance or calibration, etc.
MAINTENANCE
After the fi rst 50 hours
Oil change

TROUBLESHOOTING GUIDE

• The pump is not primed and is operating dry, without lubricant.
At start-up, the
• The water supply is off.
pump makes
• The valves are blocked.
no noise
• The delivery line is closed and does not let the air fl ow out of the pump.
• There is Insufficient air suction and/or supply.
• Bends, elbows, fi ttings on the feed line are slowing down the fl ow of the liquid.
The pipes
• The feed fi lter is dirty or too small.
pulsate in
• The booster pump, if installed, is providing an insufficient pressure and/or capacity.
an irregular
• The pump is not primed due to an insufficient head, the delivery pipe closing during
fashion.
priming and/or a valve sticking.
• Worn pressure valves and/or seals and/or transmission problems.
• The pressure regulating valves are not working properly.
The pump
• There is an insufficient supply and/or the number of revolutions is less than the rated
does not give
value.
the rated capa-
• Excessive leaking from the pressure regulating valve and/or the pressure seals.
city and makes
• Worn valves.
excessive
• Cavitation due to undersized feed pipes and/or fi lter, insufficient capacity, high water
noise.
temperature, clogged fi lter.
The pressure
• The port (nozzle) is too large or is worn.
supplied by
• Excessive leaking from the pressure seals.
the pump is
• The pressure regulating valve is not working properly and/or the valves are worn.
insufficient.
• The pump is working at an excessive pressure and/or the number of revolutions is
higher than the rated value.
The pump
• The oil in the sump of the pump is not at the required level or is not of the recom-
overheats:
mended type.
• The belt is too tight, the joint or the transmission is not aligned.
Every 500 ore
Every 1000 ore
Oil change
Checking/replacement: Valve assemblies, pumping seals.
(mean period. Reduce for severe operating conditions)
9