FAAC S418 Manual De Instrucciones página 14

Ocultar thumbs Ver también para S418:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Secure the operator to the rear bracket using the appropriate bolt
supplied, as indicated in figure 15.
7. Bring the leaf of the gate to the closure position.
8. Bring the operator, together with the related bracket,
alongside the leaf.
9. Check that the operator is horizontal using a spirit level, as
indicated in figure 16, and provisionally secure it witch clamps
or two welding points.
The axis of the securing holes of the front bracket must
be aligned with the axis of the securing holes of the rear
bracket, see figure 17. If the structure of the gate should not
permit reliable securing, the structure of the gate must be
adapted to provide a solid supporting base.
10. Prepare the operator for manual operation, see paragraph
5, and move the leaf manually, checking that it completes
the entire opening operation required, stopping at the
mechanical stops.
If, during the test, the operator should strike against the leaf
of the gate, value E may be increased, see figure 4, up to
a maximum of 115 mm, using appropriate spacers placed
between the front bracket and the leaf of the gate.
11. Perform any corrective measures necessary and repeat the
procedures from point 9.
12. Definitively secure the front bracket, using a suitable securing
system as indicated in figure 18.
If it is decided to weld the bracket directly onto the leaf, the
operator must be released temporarily. Wait for the bracket
to cool before reassembling the operator.
Fig. 14
3.5. WIRING THE OPERATOR
The operator is supplied with the cable already wired. If the cable
has to be replaced, a cable for outside mobile laying must be
Fig. 15
used ( e.g. H07RN-F).
3.6. MECHANICAL STOPS
The S418 operator is supplied with mechanical stops on opening
and closing as standard. These may be used in place of the
mechanical stop-points for the leaf. For adjustment of the stops,
proceed as follows:
3.6.1. m
echaNical stop at
1. Prepare the operator for manual operation, see paragraph
5.
2. Manually bring the leaf into the opening position.
3. Loosen the securing screw, figure 19 ref. a. The screw does
not need to be completely removed.
4. Move the mechanical stop until it is close to the front fitting,
as indicated in figure 20.
5. Tighten the securing screw once again.
The mechanical stop is coupled to a toothed sector, figure 19
Fig. 16
ref. b. In the case of obstructions during movement, check
that the coupling is free. DO NON USE FORCE.
3.6.2. m
echaNical stop at
1. Prepare the operator for manual operation, see paragraph
5.
2. Manually bring the leaf into the closing position.
3. Loosen the securing screw, figure 21 ref. a. The screw does
not need to be completely removed.
Fig. 17
4. Move the mechanical stop until it is close to the front fitting,
as indicated in figure 22.
5. Tighten the securing screw once again.
The mechanical stop is coupled to a toothed sector, figure 21
ref. b. In the case of obstructions during movement, check
that the coupling is free. DO NON USE FORCE.
12
o
peNiNg
Fig. 19
c
losiNg
Fig. 18
Fig. 20

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido