SYSTEM MAINTENANCE AND INSPECTION

The respirator should be inspected before and after use for any damage or defects that could affect the
performance of the respirator. Following the requirements outlined in 29 CFR 1910.134, the maintenance and
inspection program should assure that the user is provided with a respirator that is clean, sanitary, and in good
operating condition. The respirator wearer should inspect the equipment prior to each use to assure that it is in
proper working condition.
Never modify or alter this respirator. Repair or replace parts only with approved 3M components. Utilizing
components other than those supplied by 3M may adversely affect respirator performance and result in
sickness or death.
Carefully inspect the complete 3M
Speedglas
glass or protection plates reduce vision and can seriously impair protection. All damaged components should
be replaced immediately. Remove any protective fi lm from the visor.
Any headgear subjected to severe impact should be replaced.
ADF Functionality Check
To check for proper ADF operation, hold the ADF within a few inches of a fl uorescent light bulb and observe the
ADF switch to the selected dark state. Depending on the light source, it may be necessary to temporarily increase
the sensitivity setting. Optionally, the ADF can be triggered by pointing any television or VCR remote control
device at the ADF sensors and by pushing the "On" button.
NOTE: If the ADF does not function as described above, do not use and immediately contact your supervisor or
3M representative.
W WARNING
ADF 9100 before each use. Cracked, pitted or scratched fi lter
21
Sweatpad Replacement
See Fig. 7.
Fig. 7
22