IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always
be followed including the following:
READ AND FOLLOW ALL
SAFETY INSTRUCTIONS.
Do not mount near gas or electric heaters.
Do not attempt to service the battery. A sealed, no maintenance
battery is used that is not field replaceable. Contact the
manufacturer for information on service.
Equipment should be mounted in locations and at heights where it
will not be subjected to tampering by unauthorized personnel.
The use of accessory equipment not recommended by the
manufacturer may cause an unsafe condition.
Do not use this equipment for other than its intended use.
SAVE THESE INSTRUCTIONS
Other instructions:
The manual shall include instructions for installation, operation, and
maintenance recommended by the manufacturer. The instructions
shall warn the user that all servicing should be performed by qualified
personnel.
The installation instructions and/or product marking shall be provided with
a maximum mounting height of:
a)
21 ft. – for 2 ft version.
b)
18 ft. – for 4 ft version.
Duration of Test
1-1/2
30 Sec.
Date
Hour
All statements, technical information and recommendations contained herein are based on information and tests we believe to be reliable. The accuracy or completeness
thereof are not guaranteed. In accordance with Eaton's Crouse-Hinds Division's "Terms and Conditions of Sale," and since conditions of use are outside our control, the
purchaser should determine the suitability of the product for his intended use and assumes all risk and liability whatsoever in connection therewith.
Figure 7
Other
Battery Replaced
Inspected By
Eaton's Crouse-Hinds Division
1201 Wolf Street Syracuse, New York 13208 • USA
Copyright © 2015
EM UNV34 Fixture Dimensions

MAINTENANCE RECORD

NFPA 101 (2003) REQUIREMENTS
" A FUNCTIONAL TEST SHALL BE CONDUCTED ON EVERY REQUIRED
EMERGENCY LIGHTING SYSTEM AT 30 DAY INTERVALS FOR A MINIMUM OF
30 SECONDS. AN ANNUAL TEST SHALL BE CONDUCTED FOR THE 1-1/2 HOUR
DURATION.
EQUIPMENT SHALL BE FULLY OPERATIONAL FOR THE DURATION OF THE
TEST. WRITTEN RECORDS OF TESTING SHALL BE KEPT BY THE OWNER FOR
INSPECTION BY THE AUTHORITY HAVING JURISDICTION. "
Lamp Replaced (Record
Fixture Location)
Notes
Figure 8
IF 1740
Revision 1
New 11/15