PROGRAMMING INSTRUCTIONS

Programming Overview

The EZ Pro™ can be programmed under AC power or powered from the two AA alkaline
batteries. Before programming the EZ Pro™, it may be helpful to become familiar with some
general programming guidelines:
If a segment(s) on the LCD is flashing, it means that it can be changed by the user.
When using '+'or '–' keys, hold the button three seconds to start a fast scroll.
Be sure the appropriate program letter is displayed when you are programming; program
changes are specific to the program letter displayed on the LCD.
There is no "ENTER" key. Key-presses and dial settings are stored automatically for you.
If you make a programming change while a program is running, the program terminates
immediately. The new program starts at the next start time scheduled.
When not running, the controller displays the current time and the current day.
During manual operations, there is a 5-second delay before the operation begins. During
this time, you can change your settings. Each time you make a change, the delay resets to
5 seconds.
MANUAL, CYCLE, and 3 MINUTE TEST procedures only operate with the Program dial
set in the AUTO position.
After a test procedure runs, the controller reverts back to the AUTO procedure and runs
the next program scheduled.
The test procedures ignore the sensor connection; this allows you to water or run your
program even if the sensor has suspended operation.
9