DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing serious
injury. If oil is injected under the skin, see a doctor
immediately.
WARNING: Only use hydraulic cylinders in a coupled
system. Never use a cylinder with unconnected couplers.
If
the
cylinder
components can fail catastrophically causing severe personal
injury.
WARNING: BE SURE SETUP IS STABLE BEFORE
LIFTING LOAD. Cylinders should be placed on a flat
surface that can support the load. Where applicable, use a
cylinder base for added stability. Do not weld or otherwise
modify the cylinder to attach a base or other support.
Avoid situations where loads are not directly centered on
the
cylinder
plunger.
considerable strain on cylinders and plungers. In
addition, the load may slip or fall, causing potentially dangerous
results.
3.0 Specifications
Operating Pressure
Electric Power Source
Motor Rating
Flow Rate
Max. Operating Temperature
Model No.
PUD-1100B/E
PUD-1101B/E
PUD-1300B/E
PUD-1301B/E
PUJ-1200B/E
PUJ-1201B/E
PUJ-1400B/E
PUJ-1401B/E
becomes
extremely
overloaded,
Off-center
loads
"B" Models
15 Amp 120 V. grounded 1Ph. 50/60 Hz
Motor Rating 1/2 HP Universal, 9 Amps at
10,000 psi [700 bar] & 12,000 RPM
operates at 60-125 Volts 85-89 dBA
Used with Cylinder
Single-Acting
Single-Acting
Single-Acting
Double-Acting
Distribute the load evenly across the entire saddle
surface. Always use a saddle to protect the plunger.
IMPORTANT: Hydraulic equipment must only be
serviced by a qualified hydraulic technician. For repair
service, contact the Authorized ENERPAC Service Center
in your area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
by genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fit properly and withstand high
loads.
CAUTION: Check specifications and motor plate data.
Use of an incorrect power source will damage the motor.
produce
0-10,000 psi [700 bar] {70 mPa}
200 in.
3
/min. [3,3 l/min] at 0-200 psi [0-14 bar] {0-1,4 mPa}
20 in.
3
/min. [0,33 l/min] at 10,000 psi [700 bar] {70 mPa}
150°F [65°C]
Valve Type
Dump Valve
Dump/Hold
3-Way, 2-Position
4-Way, 3-Position
2
"E" Models
10 Amp 220 V. 1Ph. 50/60 Hz
.37 kW Universal, 4 Amps at 10,000 psi
[700 bar] {70 mPa} & 12,000 RPM 85-89 dBA
Usable Oil Capacity
122 in.
3
231 in.
3
122 in.
3
122 in.
3
122 in.
3
231 in.
3
122 in.
3
231 in.
3
Weight
31 lbs.
43 lbs.
31 lbs.
43 lbs.
27 lbs.
39 lbs.
32 lbs.
44 lbs.