Decommissioning; Teaching-In Of The Device; Teaching-In To Alpha Ip Base Station - Alpha IP RTD 61001-N1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5 Commissioning
5.1 Teaching the device
In order be integrated into the Alpha IP System and to communicate with other
devices, the room control unit Display must be taught-in first. The room control unit
Display is taught-in directly to the Alpha IP base station, or in conjunction with the
radiator thermostats, to the Alpha IP Access Point. In case of direct teaching-in, the
configuration is done on the device itself; in case of teaching-in via the Access Point,
it is done via the Alpha IP app.
5.1.1 Teaching to Alpha IP Base Station
For teach-in, keep a minimum distance of 50 cm between the devices.
The teach-in process can be interrupted by shortly pressing the teach-in key
again. This is confirmed by a short flash in red colour of the device LED.
If no teaching-in is performed, the teach-in mode is finished automatically
after 30 seconds.
If the room control unit shall be taught-in to the Alpha IP Base station, the two
devices to be linked must be set to teach-in mode.
Commissioning
37

Publicidad

Tabla de contenido
loading

Tabla de contenido