6.1.9 Configuration of Alpha IP Base station
This menu allows to configure the Alpha IP Base station in standalone operation.
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol "
wheel.
If the room control unit is taught-in to more than one base stations, select
the desired base station with the setting wheel.
The device parameters "UnP1/UnP2" and the channel parameters "ChAn" are avail-
able in the configuration menu for the Alpha IP Base station; these parameters allow
the modification of the pump lead and follow-up times, setback temperatures, time
intervals and many other parameters.
Information on the configuration possibilities can be found in the Alpha IP
Base station instructions.
6.1.10 Connection test
During this verification the room control unit Display sends a switching command to
the base station. Depending on the switching status the assigned heating zone has,
it will be switched on or off after receiving the command.
1. Press and hold the setting wheel (E) in order to open the configuration menu.
2. Select the symbol " " and confirm the selection by shortly pressing the setting
wheel.
" and confirm the selection by shortly pressing the setting
Operating modes and configuration
47