Palazzetti ECOFIRE LINDA Serie Manual De Instalación, Uso Y Mantenimiento página 83

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7.3.2 Single wall pipe and outside air intake
In this case the combustion air is taken directly
from outside, from the back of the stove.
• Remove the back panel of the stove (A)
• Remove the silencer (B)
• Remove the preform (C) on the back panel (A)
and insert the flexible hose (D) to connect it to
an outside air intake (Fig. 37).
• Tighten the hose (D) with the previously loos-
ened metal hose clamp (E)
A
C
004778560 - 06/11/2020
ITALIANO
ENGLISH
E
D
B
Fig. 37
DEUTSCH
• Remove the preform (E) on the back panel (A)
• Remove the preform (F) on the side panel (G)
• Connect the flue gas pipe (H) (Fig. 38)
• Refit the back panel (A)
A
FRANÇAIS
ESPAÑOL
G
F
H
E
Fig. 38