• Position the right refractory wall (C) in the com-
bustion chamber (Fig. 47) by slightly lifting the
bottom wall (B).
• Insert the bottom part of the right wall (C) into
the side profile of the bottom wall (B) and check
that it is inserted in the slot in the support (H)
• Refit the burn pot (I)
B
H
7.7 Electrical connection
Simply connect the appliance to the electrical
system using the supplied plug (Fig. 48).
The electrical connection (plug) must be easily
accessible after appliance installation as well.
If the power supply cable is damaged
it must be replaced by the technical
assistance service or a qualified techni-
cian in order to prevent any risk.
004778560 - 06/11/2020
ITALIANO
ENGLISH
I
C
Fig. 47
DEUTSCH
It is mandatory that the system is
equipped with an earth connection
and a differential switch in compliance
with the laws in force.
The flue gas evacuation duct must
be equipped with its own earth
connection.
7.8 Fuel optimisation
Excellent fuel depends on different factors (type
of installation, operating and maintenance con-
ditions, type of pellets, etc.)
Upon first ignition, the stove can be regulated for
best combustion performance.
Generally speaking, if at the end of combustion,
there is a lot of residue in the burn pot, you
should change the combustion configuration
(by increasing the value) until you find the best
solution.
See the function, "Fuel" in the use and operation
manual.