Festo CPV GE-ASI-4E4A CE Serie Instrucciones Para El Usuario página 25

Ocultar thumbs Ver también para CPV GE-ASI-4E4A CE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
Type CPV...−GE−ASI−4E4A−...−CE
AS−Interface bus connection
Voltage range (protected against
incorrect polarity)
Residual ripple
Max. current consumption at −5 °C
all inputs in 0−status
all inputs in 1−status (max. current
consumption by sensors)
Load voltage connection
Rated value (protected against
incorrect polarity)
Residual ripple
Current consumption for 4 valves
(at 24 V)
switching on
after current reduction (stationary)
Valves (see pneumatics manual)
Digital inputs
Design
Max. current consumption
per input
sum currents (all inputs)
Logic level
Reference potential
Response delay
1)
For max. 30 ms, all valve coils switched simultaneously
Festo CPV...−GE−ASI−4E4A−...−CE
1)
0703NH
English
DC 26.5
31.6 V
20 mVss
CPV10−...
CPV14−...
20 mA
20 mA
200 mA
200 mA
DC 21.6
26.4 V
4 Vss
CPV10−...
CPV14−...
115 mA
175 mA
55 mA
75 mA
Watchdog function active
after 40
100 ms
(see 3.5)
4 digital inputs based on
IEC 1131−2 type 2
DC 24 V, PNP,
status display (LED)
200 mA
200 mA
ON: +11
+30 V
OFF: −30
+5 V
0 V
typically 3 ms (at 24 V)
25

Publicidad

Tabla de contenido
loading

Tabla de contenido