BSC24
PROTECTION FUSES
Position
Value
F1
315 mA
FAST-BLOW
F2
6,3 A
FAST-BLOW
F3
1 A
FAST-BLOW
FUNCTION PROGRAMMING (DIP SWITCH-SW1)
The settings are stored during the rest phase (door/barrier closed).
DIP
Status
DIP 1
OFF
STEP-BY-STEP WITH STOP
DIP 2
OFF
DIP 1
ON
DIP 2
OFF
DIP 1
OFF
CONDOMINIUM
DIP 2
ON
DIP 1
ON
DIP 2
ON
ON
DIP 3
PRE-FLASHING
OFF
ON
DIP 4
SAFETY DEVICES TEST
OFF
ON
DIP 5
DURING OPENING
OFF
Type
Description
Protects the accessories and safety devices power supply.
Protects the control unit at the 24Vac power supply input.
Protects the flashlight and courtesy light output.
Function
Description
• I Start pulse:
• II Start pulse:
• III Start pulse:
• IV Start pulse:
• I Start pulse:
• II Start pulse:
STEP-BY-STEP
• III Start pulse:
During opening it does not receive other Start commands after the first
one; during Pause subsequent Start commands reload the pause time.
• I
• Subsequent Start pulses:
Pause from opening limit switch
• Start pulse during pause:
• Subsequent Start pulse:
• If Start button is held down:
DEAD MAN
• If Pedestrian button is held down OPT:
Enables pre-flashing of 2 seconds before motor activation during opening
and closing.
Disables pre-flashing.
Enables the safety deviceS TEST before activating the opening and
closing cycle. The TEST consists of temporarily cutting the power to the
devices (+SAFETY 14 terminal ) checking correct switching of the contact
(SAFETY 6 terminal).
The cycle can only start if the devices work perfectly, if not, three prolon-
ged flashes indicate the fault.
Disables the safety devices test.
When the photocell is intercepted during both opening and closing, the
door/barrier motion is locked until the photocell is freed.
PHOTOCELL
Subsequently, there is always an opening phase.
Disables the photocell function during opening.
OPEN
STOP (will not reclose automatically)
CLOSE
OPEN
OPEN
CLOSE
OPEN
Start pulse
:
OPEN
Uninfluential
Reloads the pause time (if dip 6 ON)
or CLOSES (if dip 6 OFF)
OPEN
OPEN
CLOSE
15
UK