HPC 11500 Manual De Instrucciones página 15

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Instruction Manual Pressing Tool
11500
4. Perform and inspect test presses or have the tool manufacturer check the tool and pressing jaws regularly to en-
sure proper function.
5. Keep the pressing jaws clean. Remove dirt with a brush.
In order to avoid possible malfunctions we off er you a manufacturer service consisting (see ASC) of disassembly,
cleaning, exchange of possibly worn out parts assembly and fi nal inspection. Only a clean and properly functioning
press tool can ensure a leak free connection.
The tool has no user serviceable parts. Only the pressing jaws (page I, pic. 1.8; page III, pic. 13) and battery can
be changed by the user.
Attention
Do not damage the seals of the tool. If the seals are damaged the warranty is null and void.
5.
Troubleshooting
a.) Constant fl ashing/indicating of the red LED (page I, pic 1.3) or an audible warning signal.
see table 1. If the issue cannot be resolved return the tool to the nearest Authorized Service Center (see
inside back cover).
b.) The tool is leaking oil.
Return the unit to the manufacturer. Do not open it and damage the seal of the tool.
c.) The red LED fl ashes 3x and simultaneously 3 acoustic warning signals occur (see table 1).
 
Serious fault! If this fault occurs repeatedly, return the unit to an Authorized Service Center (ASC). Do not
open it and damage the seal of the tool.
In case of a one time occurrence the fi tting has to be replaced or pressed a second time.
L611500 Rev. C © 05/2013
6
US

Publicidad

Tabla de contenido
loading

Tabla de contenido