Instruction Manual Pressing Tool
11500
2. Squeeze the trigger until the press is complete.
Note: if the red LED flashes or there an audible beep,
consult "Tab. 1."
3. Open the jaws and remove the tool from the sleeve.
4. Inspect the connection to ensure the tubing is still
properly seated (only PEX is visible in sleeve sight
hole), and the press has been properly formed onto the
sleeve (see diagram for guideline).
Tool jaws imprint "HL" on the sleeve.
An improperly positioned tool may result in a poor
press and a damaged fitting.
Sight
Hole
L611500 Rev. C © 05/2013
Improperly
PEX
positioned
improperly
jaws
seated in
sleeve
Example Presses
"
"
1
3
2
4
1
"
1
4
Pinched Stainless Steel Sleeves
If the stainless steel sleeves are being pinched, the tool jaws
are worn out or damaged and must be replaced.
1"
1
"
1
2